Problem
Terminal will not accept
incoming ISDN calls
Terminal will not make
outgoing ISDN calls
ISDN device does not operate
correctly
Terminal is connected to the
BGAN network, but cannot
obtain the requested Quality
of Service
Troubleshooting
42
3004128-0001 Revision C
Possible Cause
The MSN programmed into the ISDN device
does not match the MSN programmed into the
terminal
ISDN power sourcing is turned off
Terminal is not Registered with the Network.
The ISDN device is trying to draw too much
power from the satellite terminal's ISDN
interface
The device you are connecting is not an ISDN
device. It might be an Ethernet device that you
are accidentally connecting to the ISDN port.
Make sure that you don't have both RJ-11 and
ISDN handsets connected at the same time.
Network temporarily not available
User tried to set up a 256 Kbps streaming
connection.
Possible Solution
Ensure the appropriate
MSN is programmed into
the ISDN device, see
User Guide
Ensure the appropriate
MSN is programmed into
the terminal, see ISDN
Section of User Guide
Enable the ISDN power
sourcing from the BGAN
LaunchPad or ISDN web
UI page (unless the ISDN
device has a separate
power source).
Check the Properties page
in web UI to make sure
the unit is CS attached.
Only connect an ISDN
device that draws less
than 70mA of current at
40V (equivalent power
2.8W)
Make sure you connect
only ISDN devices to the
ISDN port
Remove one of the
handsets and reboot the
terminal.
Retry again. If problem
persists, contact your
service provider.
The Inmarsat Network
only supports 256K for
Class 10 >45 degree look
angle and 128K
connections for Class 11
UT's