Set End Code - Uniden BCD996T Owner's Manual

Scanning radio
Hide thumbs Also See for BCD996T:
Table of Contents

Advertisement

UB335ZH.book Page 72 Friday, March 17, 2006 4:35 PM
Setting the Status Bit
[MENU]
Program System
Select a Motorola Type I or II system
Edit Sys Option
Set Status Bit
Ignore — the scanner rounds all received ID's down to the next interval of 16.
The default setting is Ignore.
Yes — the scanner treats all received ID's as unique ID's.
Note: Motorola analog systems use talk group ID's in multiples of 16. ID numbers
that fall between these ID's indicate special status flags for the system. This setting
determines how the scanner will handle ID's that are not multiples of 16.
Select your setting then press
Setting End Code Operation
[MENU]
Program System
Select a Motorola Type I or II system
Edit Sys Option

Set End Code

This setting determines how the scanner handles the transmission end code sent
by most Motorola systems. Select your setting then press
Yes — the scanner immediately returns to the control channel when it detects the
end code.
Ignore — the scanner does not return to the control channel until the carrier
drops.
Note: The default setting is Yes.
Setting I-Call Operation
[MENU]
Program System
Select a Motorola Type I, II or EDACS Wide/Narrow system
Edit Sys Option
Set I-Call
This setting determines how your scanner treats I-calls while ID Searching.
On — the scanner tracks I-calls.
72
.