TEMPERATURE SETTINGS ON THE PCB

Depending on the model, there are 4 or 8 temperatures that you can select from by changing the DIPswitch
settings on the computer board without the remote controller. See the table below.
110 (T-KJr2) and 310 (T-K4) models
113 °F (45 °C)
1
2
3
4
5
6
7
8
ON
510 (T-D2) model
104 °F (40 °C)
1
2
3
4
5
6
ON
NOTE: Only change the switches with dark squares. The dark squares
indicate the direction the DIPswitches should be set to.
Location of the bank of DIPswitches on the computer board
110 (T-KJr2) / 310 (T-K4)
Computer board
DO NOT adjust the let bank of DIPswitches for the 510 (T-D2) model.
Turn off the power supply to the water heater before changing the
DIPswitch settings.
WARNING
-WITHOUT REMOTE CONTROLLER-
Temperatures settings
122 °F (50 °C)
Default
1
2
3
4
5
6
7
8
ON
Temperatures settings <Right bank of DIPswitches>
113 °F (45 °C)
1
2
3
4
5
6
ON
DIPswitches
38
131 °F (55 °C)
1
2
3
4
5
6
7
8
ON
122 °F (50 °C)
Default
1
2
3
4
5
6
ON
510 (T-D2)
Computer board
DIPswitches (Right bank)
Page
Owner's Guide
Normal Operation
140 °F (60 °C)
1
2
3
4
5
6
7
8
ON
140 °F (60 °C)
1
2
3
4
5
6
ON