SYNTIA
Notice signals (ORANGE)
Indications
Machine in pre-heating phase
for coffee, hot water and steam
dispensing.
The appliance is rinsing - wait until
end of operation
The appliance requires a descaling
cycle
Brewing unit resetting during
appliance reset
Fill the coffee bean container and
start the dispensing cycle
The machine requires replacement of
the Intenza fi lter
OK
+
-
ESC
ON
OFF
RESET
Alarm signals (RED)
Indications
Switch the machine off, wait for 30
seconds and switch it back on again.
1
Repeat 2 or 3 times.
Water circuit fi ll request
Circuit fi lling in progress
No coffee beans inside container.
No water
Saeco International Group
Causes
Causes
03 BRIEF INSTRUCTIONS
Solutions
Wait until heated
(see bar)
Wait until end of operation
Perform the descaling cycle
To enter the descaling cycle press the
aroma/pre-ground coffee key for 5
sec.
Wait for reset
Fill the coffee bean container
Replace the fi lter. This message is displayed
if the function is enabled by programming
The alarm is disabled only if it is "RESET"
by programming
Solutions
If the machine does not start, remove
brewing unit, clean it, grease it and re-
insert. If the problem persist contact the
Service Centre
Turn the knob to the cup
When the fi lling cycle ends turn the knob
back to the central position
After fi lling the coffee container, start the
cycle again
Fill the water tank