7.4.
Power/CPU disassembly
1
7.5.

Gearmotor disassembly

1
F
D
B
Saeco International Group
E
A
B
C
2
3
P
H
L
4
1) Loosen the screw shown and remove
the card protection
2) Slide out the card, removing all
connections
2
1) Loosen the screws holding the boiler pin in place,
remove it and loosen the other screws shown
2) The following are located inside the compartment
protected by the casing:
- Brew drive (A) with gears (B) and (C) for
transmission and timing of the dispensing head.
- Grounds drawer present microswitch (D).
- Brewing unit present microswitch (E).
- Microswitch (F) detecting brewing unit home and
work positions.
- Remove the gear (C) that meshes with the motor
transmission shaft
- Remove the large gear (B)
- Remove the motor (A), complete with transmission
shaft
3) Replace the gear (B), making sure that the
imprint of the arrow is aligned with the opening
containing the pin (P)
4) When replacing the motor and the transmission
shaft, make sure the bearings (L) are in the right
position.
Grease the shaft thoroughly and evenly