Safety Devices - Fujitsu AU*G07LVLA Technical Manual

Multi : 2rooms type 3rooms type 4rooms type
Hide thumbs Also See for AU*G07LVLA:
Table of Contents

Advertisement

11.

SAFETY DEVICES

Circuit protection
Fan motor protection
Compressor protection
High pressure protection
 Pressure switch (2) : For control device
Protection form
Current fuse (MAIN PCB)
Current fuse
(NEAR THE TERMINAL TO
POWER SUPPLY)
Current fuse
(NEAR THE TERMINAL TO
INDOOR UNIT)
Thermal protector
Thermal protector
Pressure switch (1)
- (04 - 75) -
Model
AO  G30L4
5A 250V
3.15A 250V
25A 250V
15A 250V
OFF :130±20°C
ON : 100±20°C
OFF : 125°C
ON : 80°C
OFF :4.2±0.10MPa
ON : 3.2±0.15MPa

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents