English
• On the left bottom side, a button to stop the beverage
brewing.
• On the right bottom side, a button to stop the current
phase and go on with the subsequent phases.
The figure shows the "Cappuccino" brewing screen.
If an anomalous condition occurs during the brewing
phase, e.g. a fault or a product shortage, a message
with the causes of the block is displayed.
Special messages and signals are indicated in chapter
"Troubleshooting".
9.3

Display messages

When one or more alarms occur, the relevant beverages
are disabled and cannot be selected for the brewing.
If a disabled beverage is pressed a timed pop-up window
appears for 3 seconds, indicating which current alarm has
disabled the beverage.
Here below the list of the alarms displayed is reported,
along with the machine conditions that release them.
72
Temperature sensor alarm
Consequence: All the beverages for which the coffee
phase is required are disabled.
Message upon touching: "Temperature sensor alarm".
Pressure sensor alarm
Consequence: All the beverages for which the water phase, the
milk phase or the steam phase is required are disabled.
Message upon touching: "Pressure sensor alarm".
Coffee grinder 1(2) blocked
Consequence: If the selected coffee grinder is blocked all
the beverages for which the coffee phase is required are
disabled; if the blocked coffee grinder is not the selected
one, the error has no consequences.
Note: In machine models which allow for the coffee bean
hoppers to be used alternatively, the blocked coffee
grinder is just not used.
Message upon touching: "Coffee grinder blocked".
Coffee alarm
Meaning: The latest grinding cycle exceeded the timeout.
Possible causes: There is no coffee; the dosing unit sensor
is out of order or disconnected (after 5 attempts).
Consequence: The "no coffee" icon is shown over the beverages
for which the coffee phase is required with either the coffee
beans from the empty hopper or the not operational dosing unit.
Message upon touching: No message.
Water alarm
Meaning: No water pressure detected.
Consequence: All beverages are disabled.
Message upon touching: "No water".
Water level alarm
Consequence: All the beverages for which the steam phase, the
milk phase or the hot water phase is required, are disabled.
Message upon touching: "Water level error".
Brew group error
Consequence: All the beverages for which the coffee
phase is required are disabled.
Message upon touching: "Brew group error".
Coffee grounds drawer present
Consequence: When it is not detected (value = 0), all the
beverages for which the coffee phase is required are disabled.
Message upon touching: "Insert coffee grounds drawer".
Front door closing
Consequence: When it is not detected (value = 0), all
beverages are disabled.
Message upon touching: "Close front door".
Pre-ground coffee door closed
Consequence: No consequence causing the disabling of
beverages. If open (value = 0), all the beverages for which
the coffee phase is required are brewed without fresh
pre-ground coffee beans (coffee quantity = 0) - see section
"Refilling with Pre-ground Coffee".