22 | Installation instructions
Adjusting minimum power fan speed (P2)
To select fan speed:
▶ Press ON/OFF button
into ON.
▶ Press and hold simultaneously buttons
seconds, until display reads P2.
Fig. 24
▶ Press
to enter P2 adjustment. The current setting will appear on
P
the display (factory default).
+
▶ Press
or
to choose the fan speed suitable with your
installation, see table 21 and table 22.
▶ Press and hold ( 5 sec.) "Program" button
flashes, then the selected value is memorized.
Proceed directly to chapter 7.5 to confirm CO
are within range.
Attention residents of the Commonwealth of Massachusetts:
In the Commonwealth of Massachusetts the following regulation went
into effect on 12/30/2005:(a)For all side wall horizontally vented gas
fueled equipment installed in every dwelling, building or structure used
in whole or in part for residential purposes, including those owned or
operated by the Commonwealth and where the side wall exhaust vent
termination is less than seven (7) feet above finished grade in the area of
the venting, including but not limited to decks and porches, the following
requirements shall be satisfied:1. INSTALLATION OF CARBON
MONOXIDE DETECTORS. At the time of installation of the side wall
horizontal vented gas fueled equipment, the installing plumber or gas
fitter shall observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the floor level where the gas
equipment is to be installed. In addition, the installing plumber or gas
fitter shall observe that a battery operated or hard wired carbon
monoxide detector with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall horizontal
vented gas fueled equipment. It shall be the responsibility of the
property owner to secure the services of qualified licensed professionals
for the installation of hard wired carbon monoxide detectors.a.In the
event that the side wall horizontally vented gas fueled equipment is
installed in a crawl space or an at tic, the hard wired carbon monoxide
detector with alarm and battery back-up may be installed on the next
adjacent floor level.b. In the event that the requirements of this
subdivision can not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with the above
requirements; provided, however, that during said thirty (30) day
period, a battery operated carbon monoxide detector with an alarm shall
be installed.2.APPROVED CARBON MONOXIDE DETECTORS. Each
carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and
IAS certified.3. SIGNAGE. A metal or plastic identification plate shall be
permanently mounted to the exterior of the building at a minimum height
of eight (8) feet above grade directly in line with the exhaust vent
terminal for the horizontally vented gas fueled heating appliance or
equipment. The sign shall read, in print size no less than one half (1/2)
inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
6 720 644 887 (2013/02)
+
or
and
for 3
P
until the display
P
values
2
Adjusting maximum power fan speed (P1)
To select fan speed:
▶ Press ON/OFF button
into ON.
▶ Press and hold simultaneously buttons
seconds, until display reads P2.
Fig. 25
▶ Press the minus button
to display P1.
▶ Press "Program" button
P
setting will appear on the display.
+
▶ Press
or
to choose the fan speed suitable with your
installation, see table21 and table 22.
▶ Press and hold ( 5 sec.) "Program" button
flashes, then the selected value is memorized.
Proceed directly to chapter 7.5 to confirm CO
are within range.
OBSTRUCTIONS".4. INSPECTION. The state or local gas inspector of the
side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon
monoxide detectors and signage installed in accordance with the
provisions of 248 CMR 5.08(2)(a)1 through 4.(b)EXEMPTIONS: The
following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:1.
The equipment listed in Chapter 10 entitled "Equipment Not Required
To Be Vented" in the most current edition of NFPA 54 as adopted by the
Board; and2. Product approved side wall horizontally vented gas fueled
equipment installed in a room or structure separate from the dwelling,
building or structure used in whole or in part for residential purposes.(c)
MANUFACTURERS REQUIREMENTS - GAS EQUIPMENT VENTING
SYSTEM REQUIRED. When the manufacturer of Product Approved side
wall horizontally mounted gas equipment provides a venting system
design or venting system components with the equipment, the
instructions provided by the manufacturer for the installation of the
equipment and the venting shall include:1. Detailed instructions for the
installation of the venting system or the venting system components:
and2. A complete parts list for the venting system design or venting
system.(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT
VENTING SYSTEM NOT PROVIDED. When the manufacturer of a product
approved side wall horizontally vented gas fueled equipment does not
provide the parts for the venting of flue gases, but identifies "special
venting systems," the following requirements shall be satisfied by the
manufacturer:1. The referenced "special venting system" instructions
shall be included with the appliance or equipment installation
instructions; and2. The "special venting systems" shall be product
approved by the Board, and the instructions for that system shall include
a parts list and detailed installation instructions.(e) A copy of all
installation instructions for all products approved side wall horizontally
vented gas fueled equipment, all venting instructions, all parts lists for
venting instructions, and/or all venting design instructions shall remain
with the appliance or equipment at the completion of the installation.
+