5 5

Framing and Clearances

A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
G
1,3 cm
J
A
D
7,6 cm
H
in.
SL350TRSI-N-CE
SL350TRSI-PB-CE
cm
Figure 5.1 Appliance Locations
20
2,5 cm GAP TO WALL ON EACH SIDE
A
B
C
TOP FLUE
ONE 90º ELBOW
REAR FLUE,
HORIZONTAL TERMINATION
TWO 90º ELBOWS
N
B
I
D
A
B
C
D
40-1/4
34
56
48-1/2
See Section D,
Mantel Projections
102,3 86,4 142,3 123,2
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
K
ALCOVE
E
INSTALLATION
ONE 90º ELBOW
REAR FLUE
NO ELBOWS
B
F
E
F
G
16-1/2 13-1/2 7-1/2 34-3/4 27-3/4
41,9
34,3
REAR FLUE
B
D
H
I
J
K
36
19,1
88,3
70,5
91,4 119,4 14,9
L
C L
M
L
M
N
47
5-7/8 68-3/4
1737