PROGRAM DESCRIPTION
M200 PARAMETERS
Mode
NORMAL
or
RECOND
Note: In NIGHT Mode the M200 operates in NORMAL Mode with reduced current and
disabled fan. The unit automatically returns to NORMAL after 8h.
6 • EN
Desulphation
Recovers a
sulphated battery
Desulphation
YES
Max 4h or until the
voltage reaches 12.6V.
Soft Start
Tests the battery
condition
Soft Start
15A for max 20h.
NIGHT Mode max 5A.
Bulk
Absorption
Peak charge with
Bulk charge
minimal fluid loss
Bulk
Absorption
14.4V until 4h after
the current dropped to
4.5A, max 16h.