Download Print this page
DELTA DORE D10 W RF Installation Instructions

DELTA DORE D10 W RF Installation Instructions

Wireless thermostat for heating control
Hide thumbs Also See for D10 W RF:

Advertisement

Quick Links

D10 W RF
Wireless thermostat for
heating control
Installation instructions
Delta Dore hereby declares that the equipment complies
with the essential requirements and other relevant provisions
of the R&TTE Directive 1999/5/EC.
The EC declaration of conformity for this equipment is available,
on request, from:
"Technical info" department
DELTA DORE - Bonnemain - 35270 Combourg (France)
Email: info.techniques@deltadore.com
Because of changes in standards and equipment, the characteristics given in the
text and the illustrations in this document are not binding unless confirmed.
• Carefully read these instructions prior to
installation.
• The unit must be installed in compliance with
current standards.
• Always switch off the mains before installing or
servicing the unit.
• Do not attempt to repair the unit yourself; after-sales
service is available.
• Check that the fastenings are suitable for the
surface to which the unit will be mounted
(plasterboard, brick, etc.).
• The diagrams provided are simplified for greater
clarity.
Protections and other accessories required by
standards are not illustrated.
Standards and good practice must be complied
with. Connected or nearby units must not
generate excessive interference (Directive
2004/108/EC).
Technical characteristics
Transmitter D10 RF
• Power supply: 2 LR03-AAA type 1.5 V alkaline batteries
• Insulation class: class III
• Transmission frequency 868 MHz (Standard EN 300 220)
• Class 1 radio equipment (can be placed on the market and
put into service without any restrictions)
• Radio range: 100 to 300 metres outside, varies depending on
the equipment linked (the range can be altered depending on
the installation conditions and the electromagnetic
environment)
• Wireless remote control device
• PI (Proportion Integral) regulation
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Dimensions: 80 x 80 x 23 mm
• Protection rating: IP30
• Installation in an environment with normal pollution levels
Receiver RF 810
• 230 V, 50 Hz power supply, +/-10%,
• Consumption: 11 VA (P=1.2 W)
• Class II insulation
• Contact output 3 A max., 230 V Cos ϕ = 1
• Automatic action: 1.C (brownout),
• Radio frequency 868 MHz (standard EN 300 220)
• Wireless range: 100 to 300 metres outside, variable
depending on the associated equipment (the range can vary
depending on the installation conditions and the
electromagnetic environment)
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Installation in an environment with normal pollution levels
• Screw mounting (standard Wallplate)
• Dimensions: 96 x 96 x 39 mm
• Protection rating: IP 40
1. Installing the RF 810 receiver
1
2
N
L
230V~
50-60 Hz
Cons. 11 VA
P = 1,2 W
4
CH
CH
OFF
ON
N
L
1
2
3
230V~
50-60 Hz
3A max. / 230V~
Cons. 11 VA
P = 1,2 W
2. Connecting the RF 810 receiver
Example 1
230V powered output
L
N
Circulator pump
CH
CH
OFF
ON
N
L
1
2
3
4
230V~
50-60 Hz
3A max. / 230V~
3
CH
CH
OFF
ON
1
2
3
4
3A max. / 230V~
4
5
Example 2
Dry contact output
L
N
N
L
1
230V~
50-60 Hz
3A max. / 230V~
6
Boiler
thermostat
input
CH
CH
OFF
ON
2
3
4

Advertisement

loading

Summary of Contents for DELTA DORE D10 W RF

  • Page 1 • Storage temperature: -10 °C to +70 °C • Operating temperature: 0 °C to +40 °C • Dimensions: 80 x 80 x 23 mm Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions • Protection rating: IP30 of the R&TTE Directive 1999/5/EC.
  • Page 2 4. Associating the Radio D10 transmitter with the receiver 3. Positioning the Radio D10 ..~1,50 m MODE > 3" Mini 20 cm > 3" NOTE: You can manually reset the receiver by pressing the button of the channel to associate for 10 seconds until the LED flashes rapidly.