Thickness adjustment dial
The dial located on top of the machine adjusts the tightness of the feeder through
which documents pass during operation. The dial has positive and negative
adjustment numbers, with 0 at the center of the adjustment range.
For normal feeding, start with 0 at the top of the dial.
To help reduce the occurrence of doubles or chains, turn the dial to the right,
so a negative number is at the top, decreasing the distance between the
rollers.
Turning the dial to the left, so a positive number is at the top, increases the
spacing between the rollers, allowing documents to pass through more easily.
Interior upper-transport plate diagrams
Upper-transport plate closed
(operating position)
*
*
Release levers
The interior upper-transport plate must be raised for jam recovery and daily cleaning.
The upper-transport plate is accessed by lifting the display panel, and it is disengaged
by pressing down on the release levers. After disengaging, lift the upper-transport
plate to the open, locked position, as shown above. To close the upper-transport plate,
press down on the release levers to unlock it from the open position. Next, push down
on the upper-transport plate until it locks in the closed position.
6 | JetScan iFX
®
i100 scanner | Diagrams
Upper-transport plate open
*
*
(locked position)
*