TECHNICAL PARAMETERS – Tower Model
PARAMETERS /
UPS TYPE
1)
Output power
Working environment
2)
Operating temperature
Storage temperature
Relative humidity for operation
Relative humidity for storage
Altitude (above sea level)
Maximum length of outgoing cables
MAINS OPERATION MODE
4)
Input voltage
Frequency of input voltage
Range of output voltage
Switching thresholds: mains – UPS
Shape of output voltage
Filtering of output voltage
Time to switch to UPS
BATTERY MODULE (BATTERY) OPERATION MODE
Output voltage (effective value)
Shape of output voltage
Switching thresholds: UPS – mains
Frequency of output voltage
Filtering of output voltage
Shorting protection
Overload protection
Time to switch back to mains operation
Support time 100%/80%/50%P
Battery
Maximum charging time
MECHANICAL PARAMETERS
Dimensions (h x w x d) [in mm]
Weight
EQUIPMENT
Number of outlet sockets
Signalling
Circuit breaker
Telecommunications filter
Communication interface
Note: The manufacturer reserves the right to change the abovementioned parameters without prior notice.
Notes:
1)
For normal operation of the UPS the load connected to its output should not exceed 80% of value indicated in the table.
Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load
current.
2)
Continued exposure of the UPS to the temperature of the surrounding exceeding +25° C will shorten the life of batteries.
3)
If the altitude above sea level increases beyond the provided limit the permitted load power of the batter battery module
decreases.
4)
The
user
change
(provided in parentheses)
2010/01/26
SINLINE series UPS – Instruction Manual
SINLINE
800
800VA/
520W
3)
4)
4)
4)
5/7/12 min
max
2 x 5 Ah
5 h
14 kg
the
switching
thresholds
SINLINE
SINLINE
1200
1200VA/
1600VA/
780W
1040W
Office or industrial rooms with low level of pollution
+10 ÷ +35 ° C
0 ÷ +45 ° C
20 ÷ 80 % (without condensation)
20 ÷ 95 % (without condensation)
up to 1000 m
< 10 m
~160 ÷ 264 V (~145 ÷ 280 V) ± 2 %
45 ÷ 55 Hz ± 1 Hz
~184 ÷ 264 V (~167 ÷ 280 V) ± 2 %
~160 V / ~264 V (~145V / ~280 V) ± 2 %
Sinus
Noise filter RFI/EMI varistor damper
<3 ms
~230 V ± 5 %
Sinus
~165 V / ~259 V (~150 V / ~275 V) ± 2 %
50 Hz ± 1 Hz
Electronic
Electronic
0 ms
4,5/6/10 min
4/5/8 min
2 x 7 Ah
3 x 5 Ah
7 h
190 × 165 × 480
16 kg
Acoustic and visual (LEDs)
Fuse 5x20mm 10 A
Available
RS 232
by
setting
standard
or
SINLINE
1600
2000
2000VA/
1300W
LC
4/5/9 min
3/4/8 min
4 x 5 Ah
5 h
5 h
190 × 165
20 kg
23 kg
4
Circuit breaker 15 A
enhanced
thresholds,
www.ever.eu
SINLINE
3000
3000VA/
1950W
4 x 7 Ah
7 h
× 640
28 kg
respectively
25