New Log Events; Digi Functions Programming With Point Id; Tone Security Option - GARDINER TECHNOLOGY Gardtec 800 Installation Instructions Manual

Hide thumbs Also See for Gardtec 800:
Table of Contents

Advertisement

Miscellaneous

New Log Events

Two new log events have been added with the implementation of Point ID these are:-
Alarm Abort
The LCD display will show "Alarm Abort" along with the time and date whilst the LED
will show " AA "
Test Call
The LCD display will show "Test Call Sent" along with the time and date whilst the LED
display will show " tC "
Access to programming the Point ID event actions is gained through the "Program
Channels " options. After D1 & D2 and the polarity options have been programmed the
following new options will be presented for programming.
Note:
All these options are defaulted to off and should be turned on as
required.
Set
Alrm
Unset
24Hr
E/E
12Hr
Tamp
AC
LF
Fire
W/D
Duress
Zone Remove
Alrm-Restore
AC-Restore
LF-Restore
After-Alarm
Abort-Call
If the After Alarm option is turned on Point ID reports for all options are sent
regardless of whether they are turned on or off following the first alarm event. This will
continue until an Set/Unset event takes place. Note: Alrm=On must be programmed for
this option to work.
Note:
Options that are turned on will send messages regardless of alarm status.
Note:
Power-Fail refers to Aux Fuse fail and will reported as Lo-Batt to the central
station.
Note:
Part-Sets will be reported as Armed Stay to the central station
Note:
Output Module tampers will be reported as Expansion Module Tamper to the
central station.
Page
GARDTEC 800 Series
PA
Bat
Alert
80
GARDTEC 800 Series
Engineer Code Entered
New Log Event of Engineer Code Entered has been added
to all models.
Digi Functions
Programming With Point ID
All normal Digi functions should be programmed as usual with the exception of the
following items that have no function with Point ID protocol.
O/C Channel Select
Restore Report Channel Select
Input Mapping and Polarity
580 Re-mapping

Tone Security Option

The option of Tone Security has been added to the ProDigi. This option is only
applicable when the ProDigi is being used in Point ID mode. When the option is set to
'Tone Security = High' a tone test will occur after any command is used (e.g Set,
Unset, Code Entry). This is in addition to the Tone Test using the Tone Test Time
option.
Page
Miscellaneous
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gardtec 816Gardtec 840

Table of Contents