Programming
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
11
00 - 99 Seconds
Final Set
Delay
12
00 - 99 Seconds
[A1] Full Set
Exit Time
13
00 - 99 Seconds
[A1] Part1
Exit Time
14
00 - 99 Seconds
[A1] Part2
Exit Time
15
00 - 99 Seconds
[A1] Part3
Exit Time
16
(00) Exit Terminator Button
(02) Time + Entry/Exit Door
[A1] Full Set
Mode
17
(00) Exit Terminator Button
(02) Time + Entry/Exit Door
[A1] Part1
Set Mode
18
(00) Exit Terminator Button
(02) Time + Entry/Exit Door
[A1] Part2
Set Mode
19
(00) Exit Terminator Button
(02) Time + Entry/Exit Door
[A1] Part3
Set Mode
20
(00) Fire
(01) P.A
(03) Off
Alert 1
Note: This feature must be enabled using option No.56
Mode
21
(00) Fire
(01) P.A
(03) Off
Alert 2
Note: This feature must be enabled using option No.57
Mode
22
(Left Digit LED)
(00) No Keyswitch
Keyswitch/
(01) Biased Keyswitch
No of RKPs
(02) Normal Keyswitch
(03) Locked
Page
GARDTEC 800 Series
Default
03
Seconds
(03)
30
Seconds
(30)
30
Seconds
(30)
30
Seconds
(30)
30
Seconds
(30)
(01) Entry/Exit Door
Time
(03) Time
(03)
(01) Entry/Exit Door
Time
(03) Time
(03)
(01) Entry/Exit Door
Time
(03) Time
(03)
(01) Entry/Exit Door
Time
(03) Time
(03)
(02) Alert
Off
(03)
(02) Alert
Off
(03)
(Right Digit LED)
No K/S
1 - 4 Number of Keypads
1 Keypad
(01)
56
GARDTEC 800 Series
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
23
00 - 99 Activations
No. Of
Note: If this option is programmed to 0 the Bell will not activate
Bell Arms
24
00 - 99 Minutes
[Area1] Bell
Note: If this option is programmed to 0 the Bell will not activate
Ring Time
Note: Local environmental legislation should be checked
25
00 - 99 Minutes
[Area1] Bell
Note: Bell delay is overridden in the event of a linefault
Delay Time
26
(00) SCB
(01) SAB
Bell
Note: All Gardiner Technology Bell Boxes (including SCB types) should
Type
use the (01) SAB setting.
27
(00) Off
(01) On
Bell Tamper
Ring
28
00 - 99 Seconds
Entry
Time 1
00 - 99 Seconds
29
Entry
Time 2
30
00 - 99 Seconds
Digi
Note: Digi Start Delay applies to Part Set system
Start Delay
31
(00) Off
(01) Zone Tamper
(03) Alert
(04) Fire
D1 Output
(06) Open/Close (07) Panic
Mode
(09) Alarm B
(10) Alarm Abort
(12) Watchdog
(13) Mains Fail
(15) Area 2 Alarm (16) Area 3 Alarm
(18) O/C Area 2
(19) O/C Area 3
(21) Alrm B Area1 (22) Alarm B Area2
(24) Alrm Abort A1(25) Alarm Abort A2
(27) Panic Area 1 (28) Panic Area 2
(30) Fire Area 1
(31) Fire Area 2
32
As D1 Output Mode (Option 31)
D2 Output
Mode
33
(00) Positive Start (01) Negative Start
Digi Output
Note: All Digi outputs (including D1 D2) are open collector outputs with
Start
10 Ohm resistor in series, some Digis may require 6K8 pullups
Page
Programming
Default
99
Activations
(99)
20
Minutes
(20)
00
Minutes
(00)
SAB
(01)
On
(01)
30
Seconds
(30)
10
Seconds
(10)
00
Seconds
(00)
(02) General Tamper
Off
(05) Part-Set
(00)
(08) Alarm
(11) 12V Power Fail
(14) Area 1 Alarm
(17) O/C Area 1
(20) O/C Cleaner
(23) Alarm B Area 3
(26) Alarm Abort A3
(29) Panic Area 3
(32 Fire Area 3
Off
(00)
Negative
Start
(01)
57