GARDINER TECHNOLOGY Gardtec 800 Installation Instructions Manual page 32

Hide thumbs Also See for Gardtec 800:
Table of Contents

Advertisement

Programming
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
53
(00) Off
(01) On
Service
This option should be used in conjunction with option 54
Timer
54
00 - 99 Weeks
No. Weeks
This option should be used in conjunction with option 53
to Service
55
(00) Off
(01) On
Zone
Log Limit
56
(00) Off
(01) On
Enable Alert
Note: Use option 20 to select mode of Alert 1 Keys
1 Keys 1&3
57
(00) Off
(01) On
Enable Alert
Note: Use option 21 to select mode of Alert 1 Keys
2 Keys 7&9
58
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
1 Mode
change the setting for the selected channel.
59
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
4 Mode
change the setting for the selected channel.
60
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
5 Mode
change the setting for the selected channel.
61
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
6 Mode
change the setting for the selected channel.
62
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
7 Mode
change the setting for the selected channel.
63
As Option 31 (D1 Output Mode)
Digi Channel
For LCD use YES key to move to desired channel and the NO key to
8 Mode
change the setting for the selected channel.
64
(Left Digit LED)
(0) Restore Off / Part Alarm Comms Off
Comms in
(1) Restore On / Part Alarm Comms Off
Part Alrm/
(2) Restore Off / Part Alarm Comms On
Restore/
(3) Restore On / Part Alarm Comms On
Abort
Page
GARDTEC 800 Series
Default
Off
(00)
00
Weeks
(00)
On
(01)
Off
(00)
Off
(00)
Off
(00)
(00)
Off
Off
(00)
Off
(00)
Off
(00)
Off
(00)
(Right Digit LED) Abort Time
Restore Off
0 - 9 x 20 Secs
Part Alrm
e.g 1=20 Secs
2=40 Secs...........
Comms On
Abort=60
Secs
(23)
60
GARDTEC 800 Series
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
65
Once in test mode with LCD display will show the number of channels
available press the corresponding number keys to activate and again to
Digi
restore, (the number of channels shown is dependant on the type of
Test Mode
communicator programmed e.g 4 for Normal Digi, 8 for Modem or ProDigi
Once in test mode with LED display will show C- press the number keys
corresponding to the desired channel to activate and again to restore.
Note: No access to test mode with an outstanding Alarm
Note: With both types of display use the 0 key to escape test mode.
66
(00) Entry/Exit zones are Entry/Exit in Part Set
(01) Entry/Exit zones are 12Hr in Part Set
Entry/Exit
Zone in
This option determines how ALL E/E zones will act in Part-Set(s)
Part Set
67
(00) Unlocked
(01) Locked
Note: Caution should be used with this option, once the engineer
Engineer
code has been locked-in it may only be unlocked/changed by use
Code
of the programmed code.
Lock-In
DEFAULTING THE PANEL WILL NOT UNLOCK THE CODE.
68
(00) Off
(01) Full Set Only
Strobe
Note: If this option is used the strobe will confirm the final setting of the
Setting
Conformation
69
(00) Off
(01) On
Note: To use this option the setting mode must be programmed to Time +
Auto
E/E. If the E/E door is opened/closed during the exit period the system
Part Set
will full set, if not the system will part set 1.
70
(00) Off
(01) On
Part Set
Note: If part set bells are programmed to OFF no bell output will be given
Bells
when the system is PART-SET.
71
(Left Digit LED)* 1
Area
(0) Area 1
Programming
(1) Area 2
Chime &
(2) Areas 1+2
Forced Walk
(3) Area 3
Test
(4) Areas 1+3
(5) Areas 2+3
Allocation
For LED
(6) Areas 1+2+3
* 1 Note: With LCD this option will appear the same as option 51
Only
Displays
* 2 Note: With LCD chime is via the Part/Test/Chime option 52.
72
(00) 816 ZEX
(01) 840 ZEX
Zone
Note: 816 may use 816 or 840 Zone Expanders
Expansion
(00) 840 ZEX
(01) ID
Type
Note: 840 may use 840 or ID Zone Expanders
73
Press YES to Auto-Map Devices on SAD1
Map ID
Press NO to Manually Map Devices on SAD1
Devices On
SAD 1
Page
Programming
Default
Entry/Exit
in Part Set
(00)
Unlocked
(00)
(03) Any Set
Off
(00)
system.
Off
(00)
(01)
On
(Right Digit LED)* 2
Area 1
FWT Off
(0) FWT Off - Chime Off
Chime Off
(1) FWT Off - Chime On
(00)
(2) FWT On - Chime Off
(3) FWT On - Chime On
816 ZEX
(00)
ZEX
(00)
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gardtec 816Gardtec 840

Table of Contents