Programming
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
34
(00) None
(01) Gardiner
Digi Type
(00) None
(01) Gardiner
(04) Mod+PID
(00) None
(01) Gardiner
(04) Mod+PID
(05) Mod+FF
Note: In all cases. Factory fitted link between 12V & Linefault terminals must
be removed if Modem or ProDigi is being used or programmed.
35
00 - 09
Key Beep
Volume
36
(00) Off
(01) On
Multi
Turn this option On when more than 4 keypads are used
Keypad
37
00 - 99 Minutes
D/Knock
Time
Window
38
4 - 6 Digits
Engineer
Code
39
(00) Remote Reset Off
Note: If Remote reset is used in conjunction with RedCare the Remote
Remote
Reset line to the panel should be connected to Line Fault source terminal
Reset
that has been selected via option 127
40
(00) 24Hr
(01) Always Off
(03) On If Unset
(04) FLT If Off
Linefault
Note: If Modem or ProDigi is used on shared line program Linefault
Sounders
Sounders to On If Set or Off.
41
(00) Detect In Exit (01)Ignore In Exit
Linefault
Note: Detect In Exit will prevent setting of system if a Linefault is present.
In Exit
Ignore In Exit will only warn.
42
(00) Off
(01) Limited
Linefault
Log
43
(00) Off
(01) On
Duress
Mode
44
As Output Expander Modes (Option 83)
Sensor
Output
Note: The term Sensor Output refers to the DET RESET terminal.
Mode
Page
GARDTEC 800 Series
Default
(02) Normal
(03) Mod+FF
Normal
(02)
(02) Normal
(03) Mod+FF
(02) Normal
(03) Point ID
Activations
(05)
Off
(00)
01
Minutes
(01)
1234
(1234)
(01) Remote Reset On
Off
(00)
(02) On If Set
Always
(05) Beep If Off
Off
(01)
Ignore
In Exit
(01)
(02) Exit/Set
Limited
(01)
On
(01)
Pulse
Off
(00)
58
GARDTEC 800 Series
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
45
(00) Constant
(01) Timed
Internal
Note: The term Internal Sounder refers to the Speaker Output
Sounder
Mode
46
(00) Any Code
(01) Master Code
(03) Engineer Code
[Area1]
(05) Main Code
Alarm
Reset
47
(00) Any Code
(01) Master Code
(03) Engineer Code
Tamper
(05) Main Code
Reset
48
(00) Off
(01) On If Key pressed
(02) On In E/E or if Keypressed
Backlight
Mode
49
(00) Off
(01) On
Zone
Note: This option determines zone rearm after an alarm
Re-Arm
50
(00) 8 (4 Wire)
(01) 16 (EOL)
Onboard
Note: Refer to options 72, 75 & 76 for programming Zone Expanders &
Zone
Zone Expander Wiring Modes for 816 & 840
Wiring
51
(Left Digit LED)
(0) 12Hr
Zone Types,
(1)Entry/Exit
Zone
(2) Access
Remove,
(3) Panic
Zone
(4) 24Hr
D/Knock
(5) Fire
(6) Alert
Enter zone
(7) Exit Terminator Button
No. followed
(8) Part Entry/Exit
by YES to
(9) Monitor
gain access
Note: Expansion wiring needs to be programmed first via option numbers 72 to 82
to zones.
When
Note: Refer to option 52 for zone attributes.
finished use
0 to escape
Note: Refer to option 71 for Area and Chime attributes.
52
(Left Digit LED)
(0) Full Set
Test/
(1) Part 1 Set
Part Sets/
(2) Part 2 Set
Cleaner
(3) Part 3 Set (Parts 1&2)
(4) Full Set + Cleaner
(5) Part 1 Set + Cleaner
(6) Part 2 Set + Cleaner
(7) Part 3 Set (1&2) + Cleaner
For LCD screens press NO to initial screen, then enter zone No followed by YES or
NO to add or remove zone in Test or Part screens.
Page
Programming
Default
Constant
(00)
(02) Anti-Code
Master
(04) Engineer + Anti-Code
Code
(01)
(02) Anti-Code
Any
(04) Engineer + Anti-Code
Code
(00)
On in
(03) Always On
E/E or if
Keypress
(02)
On
(01)
(02) 16 (2 Wire)
8 (4 Wire)
(00)
(Right Digit LED)
Zone1
(0) Removable
E/E
Non-Rem
(1) Non-Removable
(2) Removable D/Knock
Zone2
(3) Non-Removable D/Knock
Access
(4) Off
Non-Rem
(5) Normal Key Zone
Z1 (11)
(6) Biased Key Zone
Z2 (21)
All
Others
12Hr
Non-Rem
(01)
(Right Digit LED)
Off Test
(0) Off Test
(00)
(1) On Test
Prompt for LED is n- Enter zone
No YES then setting YES
For LED Chime & FWT is via
option 71