Zone Expander Cards - GARDINER TECHNOLOGY Gardtec 800 Installation Instructions Manual

Hide thumbs Also See for Gardtec 800:
Table of Contents

Advertisement

Wiring Connections
Fig. 26
Single Detector
Gardscan, Shockgard etc.
Alarm
Alarm
TMP
TMP
+
-
4K7 Resistor
6K8 Resistor
Alarm
+
-
Aux
Zone
Fig. 28
Double Contact
Alarm
Alarm
TMP
Use Two Silver
Any Brass Screw
Screws For Alarm
For Tamper
4K7 Resistor
6K8 Resistor
Alarm
Alarm
Use Two Silver
Screws For Alarm
6K8 Resistor
Alarm
Zone
Page
GARDTEC 800 Series
Fig. 27
Double Detector
Gardscan, Shockgard etc.
Alarm
Alarm
TMP
TMP
+
-
4K7 Resistor
6K8 Resistor
Alarm
Alarm
TMP
TMP
+
-
Wire Link
6K8 Resistor
Alarm
+
-
Zone
Aux
Fig. 29
Single Contact
Alarm
Alarm
TMP
Use Two Silver
Any Brass Screw
Screws For Alarm
For Tamper
4K7 Resistor
6K8 Resistor
Alarm
Zone
38
GARDTEC 800 Series

Zone Expander Cards

Two types of zone expander cards are available, the Gardtec 816 Expander Card that
may only be used on the 816 and the Gardtec 840 Expander that may be used on the
816/840.
Up to eight zone expander cards may be fitted to the Gardtec 840 and two on the 816
control panel. If required one of these expander cards may be plugged directly onto the
the main PCB, the other expander cards then being wired to the plug-on card as
shown in Fig. 30. Four cores are required for interconnection of the zone
expanders. If Output Expanders are to be used ( 840 only ) on the same leg as
zone expanders an extra core will be required.
Fig. 30a Gardtec 840 Expander Card Wiring 'Daisy Chain' Format
Expander1 (Plugged on)
Expander2
12V
0V
SAD 1
SCLK
Fig. 30b Gardtec 816 Expander Card Wiring 'Daisy Chain' Format
Expander1 (Plugged on)
Expander2
12V
0V
SADIN
SCLK
The expander cards may also be wired back to the onboard expander card in 'Star'
format (each expander card wired back individually).
Alternatively all the zone expander cards may be wired to the main PCB via an
optional zone expander cable Part No. 01-094. If the 816 Expander Cards are being
used two expander cables will be required. When using the zone expander cable the
following colours should be used (see Figs 31a, 31b).
If Output expanders are used ( 840 only) all SAD 2 connections should be
interconnected. If the expanders are remote from the main PCB a second expander
cable will be required to plug onto PCB EXP2 socket. The SAD2 connection on this
second cable is the yellow core.
Page
Wiring Connections
840
840
Expander3
To Others
12V
12V
0V
0V
SAD 1
SAD 1
SCLK
SCLK
12V
0V
SADIN
SCLK