Wiring Connections
Fig 10. Multiple RKPs 'Daisy Chain' format.
RKP 2
RKP 1
NOTE: RKP terminal positions may differ (dependent on model)
Fig 11. Multiple RKPs 'Star' format.
RKP 1
RKP 2
NOTE: RKP terminal
positions may differ
(dependent on model)
Page
GARDTEC 800 Series
Control Panel
12V
0V
CLK
DATA DATA
SPKR
A
B
Control Panel
12V
0V
CLK
DATA DATA
SPKR
A
B
To other RKPs
18
GARDTEC 800 Series

Keypad Jumper Options

Keypad Numbering (ident)
All keypads must have the ident jumper in position in order that the system can
recognise the keypad it is communicating with. This information is written to the log as
the system is set and unset. If greater than four RKPs are required on the 840 the Multi
Keypad option should be programmed to On, two keypads may then share the same
ident. It should be noted that LCD & LED RKPs may not share the same ident.
LCD and LED versions
Four jumper links are fitted on the LCD and LED versions of the keypad. On earlier
Standard keypads the legend was slightly different as shown in Fig 12.
Fig 12. Keypad ident legends.
KEYPAD No.
4
3
2
1
Early Legend
Note: Contour keypads fitted with ACE have two additional jumpers for the ACE
functions, these are:-
US
This jumper is the user select. With the jumper link removed each
ACE key fob will occupy one user code from the system, this is
termed as high security mode.
With the jumper link in position the ACE will occupy one user code
from the system but up to fourteen key fobs may be programmed
into the ACE, this is normal security mode.
NVM
With this jumper in position the NVM contents will be cleared when
the unit is powered up. All codes will be lost
The ident jumper should be positioned across the pins in one of the positions before
the system is powered up.
Gardtec 800 Series Compact RKP
The keypad ident on the compact RKP is through JP 1 to JP 4 respectively.
Page
Wiring Connections
A4
JP1
A3
JP2
A2
JP3
A1
JP4
Standard/Contour Legend
(Use left hand legend)