Wiring Connections

Output Expander Modules (OPX)

Up to four output expander modules may be fitted to the Gardtec 840 control panel.
These modules may, if required be wired in a chain of zone expanders or on a
separate leg(s). The zone expanders only require four cores for interconnection,
if Output Expanders are used on the same leg five cores will be required (see
page 38).
Two types of module are available:-
Four open collector outputs. Max current sink 350mA each.
Four change over relays. Contact rating 1A 12V (resistive).
Each Output Expander (OPX) has a bank of four jumper switches labelled OPX1 to
OPX4. The output allocation is as follows:-
Jumper Position
Output No (LCD)
OPX1
OP1
OPX1
OP2
OPX1
OP3
OPX1
OP4
OPX2
OP1
OPX2
OP2
OPX2
OP3
OPX2
OP4
OPX3
OP1
OPX3
OP2
OPX3
OP3
OPX3
OP4
OPX4
OP1
OPX4
OP2
OPX4
OP3
OPX4
OP4
Notes: If required, two expander cards may be configured on the same ident to
enable duplication of outputs.
When using any devices that consume current, consideration MUST be
given to the overall current available from the control panel.
Additional PSUs may be connected to the EXT PSU terminals on the
transistorised version. If this option is used the PSU (JP6) jumper
should be moved to the EXT position.
The invert link on the card will invert all the outputs of the card.
Page
GARDTEC 800 Series
Output No (LED)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
46
GARDTEC 800 Series

ID Expanders

The Gardtec 840 ID Expander card allows thirty detectors to be fitted on a four wire
run using industry standard ID biscuits or ID compatible devices. Two ID expander
cards can be fitted to the control panel. The control panel zones may still be pro-
grammed as 'Normal (4 wire)', 'Two Wire' or 'Two Wire EOL. When used to full capaci-
ty this allows the Gardtec 840 to have up to 16 control panel zones plus 60 ID zones.
Each ID expander may be wired back to the control panel with standard alarm four
core cable.
Wiring Configurations
Several configurations may be used for wiring the ID expanders to the control panel,
these are:-
One ID Expander onboard the control panel PCB.
The expander is simply plugged across the molex pins marked as EXP1 and EXP2
One ID Expander remote from the control panel PCB.
This will require a Remote Expander cable (Part No. 01-094). This cable is plugged on
to EXP1 with the Red wire to pin 1 and is wired to the ID Expander.
One ID Expander onboard the control panel PCB and one ID Expander remote
from the PCB.
The first module is plugged across the molex pins on the control panel PCB marked as
EXP1 and EXP2. The second module is then wired to the first.
Fig 32 ID Biscuit Wiring Diagram
L+
Yellow
ID Biscuit
Tamper
Switch
White
N/C alarm
Relay Contacts
Blue
L-
Fig33 Detector Using Wired ID Biscuit
White
Blue
ID Biscuit
Yellow
+
-
TAMPER
ALARM
Supply+
Supply-
L+
L-
Page
Wiring Connections
Full wiring details are
supplied with the ID Expander
Board
Zone No's 21 - 50 are on ID
card 1 (SAD1)
Zone No's 51 - 80 are on ID
card 2 (SAD2)
Fig34 Wired ID Biscuit for Contact/PA
Blue
Yellow
White
Reed Switch
(PA / Contact)
Supply+
Supply-
L-
L+
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gardtec 816Gardtec 840

Table of Contents