GARDINER TECHNOLOGY Gardtec 800 Installation Instructions Manual page 33

Hide thumbs Also See for Gardtec 800:
Table of Contents

Advertisement

Programming
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
74
Press YES to Auto-Map Devices on SAD2
Map ID
Press NO to Manually Map Devices on SAD2
Devices On
SAD 2
75
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 1
Note: This option determines the wiring method for ZEX 1.
Wiring
Each ZEX may use a different wiring method.
If 840 Zex ensure correct ident is selected on the ZEX
76
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 2
Note: This option determines the wiring method for ZEX 2.
Wiring
Each ZEX may use a different wiring method.
If 840 Zex ensure correct ident is selected on the ZEX
77
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 3
Note: This option determines the wiring method for ZEX 3.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
78
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 4
Note: This option determines the wiring method for ZEX 4.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
79
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 5
Note: This option determines the wiring method for ZEX 5.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
80
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 6
Note: This option determines the wiring method for ZEX 6.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
81
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 7
Note: This option determines the wiring method for ZEX 7.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
82
(00) 4 (4Wire)
(01) 8 (EOL)
(03) Off
ZEX 8
Note: This option determines the wiring method for ZEX 8.
Wiring
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
Page
GARDTEC 800 Series
Default
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
(02) 8 (2 Wire)
Off
(03)
62
GARDTEC 800 Series
Gardtec 800 Series Programming Guide
Option No/
Available Options
Description
(800 & 816
(00) Pulse-Off
(01) Pulse-On
options are
(03) Alarm
(04) After Alarm
referred
(06) Pulse-On-Set
(07) Part-Set
from options
(09) Mains Fail
(10) Bell
1 & 44)
(12) Latch
(13) Any Digi
(15) E/E
(16) Timed On/Off
83
(18) Alarm-B
(19) Alarm Abort
(21) Panic
(22) Gen. Tamper
Output
(24) Power-Fail
(25) Watchdog
Expander
(27) O/C Cleaner
(28) Any Closed
Modes (840)
A1
(00) Off
(04) Latch A1
For LED
(16) Pulse On A1
(20) Set A1
Prompt is n-
(37) Walktest A1
(74) Part Set A1
Enter output
(55) Int Sounder A1
(44) E/E A1
No. 1-16 then
(76) Zone Alert A1
(77) Fire Zone A1
YES. To
(33) O/C A1
(25) Alarm A1
change
(52) Alarm Abort A1
(79) Zone Tamper A1
setting press
NO then
A2
(00) Off
(05) Latch A2
enter new
(17) Pulse On A2
(21) Set A2
setting then
(38) Walktest A2
(80) Part Set A2
YES
(56) Int Sounder A2
(45) E/E A2
(82) Zone Alert A2
(83) Fire Zone A2
For LCD
(32) O/C A2
(26) Alarm A2
Press NO
(53) Alarm Abort A2
(85) Zone Tamper A2
Choose area
option then
A3
(00) Off
(06) Latch A3
use NO to
(18) Pulse On A3
(22) Set A3
scroll to
(39) Walktest A3
(86) Part Set A3
required
(57) Int Sounder A3
(46) E/E A3
setting.
(88) Zone Alert A3
(89) Fire Zone A3
(35) O/C A3
(27) Alarm A3
(54) Alarm Abort A3
(91) Zone Tamper A3
All
(00) Off
(60) Closed All
(62) Alarm B All
(63) Abort All
Any (00) Off
(09) Timed 1
(59) Timed 3
(73) Closed Any
(15) Pulse On
(28) After Alarm
(40) Pulse @ Set
(07) Int Sounder
(01) Bell
(10) Alert
(65) Any Panic
(24) Alarm
(51) Alarm Abort
(66) O/C Cleaner
(67) General Tamper (68) Zone Tamper
(02) Strobe
(03) Any Latch
(70) Power Fail
(71) Watchdog
84
00 - 23 Hrs
Timer 2
Turn On
Time (Hrs)
Page
Programming
Default
(02 Set)
Various
(05) Unset
dependant
(08) Walk-Test
on option
(11) Strobe
(14) Int. Sndr
(17) Alert
(20) Fire
(23) Zone Tamper
(26) Set Cleaner
(29) Off
(12) Pulse Off A1
(29) After Alarm A1
(41) Pulse @ Set A1
(75) Bell A1
(78) Panic Zone A1
(48) Alarm B A1
(13) Pulse Off A2
(30) After Alarm A2
(42) Pulse @ Set A2
(81) Bell A2
(84) Panic Zone A2
(49) Alarm B A2
(14) Pulse Off A3
(31) After Alarm A3
(43) Pulse @ Set A3
(87) Bell A3
(90) Panic Zone A3
(50) Alarm B A3
(61) Alarm All
(58) Timed 2
(11) Pulse Off
(36) Walktest
(08) E/E
(64) Any fire
(47) Alarm B
(23) Set Cleaner
(69) Part Set
(19) Any Set
(72) Mains Fail
00
Hours
(00)
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gardtec 816Gardtec 840