6 - Connecting the receiver
Controlling a reversible heat pump
Reversible heat pump
Reversible heat pump
with thermostat input
with thermostat heat input
and summer / winter Input
and thermostat cool input
N
230 V
L
Underfloor
Underfloor
heating
heating
Hydraulic kit
output
output
Thermostat
input
Summer /
winter Input
Summer /
winter switch
Geothermal OR Air source
Geothermal OR Air source
Select cabling that is suitable for your heat pump or refer directly to the manufacturer's
specifications.
8 - Configuration
Example: If the tem-
perature displayed by
the unit is 19°C and
the temperature mea-
sured is 20°C, add
1°C to the display then
confirm by pressing
OK.
Enter your desired setting using the + or - buttons Press OK
to confirm and move on to menu CF02
Automatic mode temperature display option
Continuous set-point temperature display.
With this option, press i to display the
room temperature.
Continuous room temperature display.
With this option, press i to display the
set-point temperature.
Enter your desired setting using the + or - buttons.
Press OK to confirm and move on to menu CF03
Control time base
Select the time base recommended for your type of installation
15 min (recommended for controlling convectors or
traditional radiators).
30 min (recommended for controlling heat pumps,
depending on the model)
45 min (recommended for controlling heat pumps,
depending on the model)
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF07
Home automation functions in the installation (optional)
No home automation functions
Home automation features associated with the RF
640 receiver
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF08
-
Press on the
button of the TYBOX 610 RF.
The receiver LED stops flashing.
The thermostat is associated with the receiver.
Press OK to go on to the menu CF09.
Radio transmission test
With this mode, you can test the correct
operation of your installation.
• The unit displays tESt and sends out a radio
signal every 3 seconds to the receiver.
• Place the TYBOX 610 RF in the room where
you would like to use it, and check for the
correct transmission of the radio signal to the
receiver (its OK LED flashes each time a radio
signal is received). The radio transmission is
operational.
If the receiver does not pick up the transmissions, move the thermostat so that you obtain
a suitable radio reception.
Press on OK to exit the test mode or turn the control selector dial to another position
Reversible heat pump
with thermostat input
and Summer / winter switch
N
230 V
230 V
L
Underfloor
heating
Hydraulic kit
Hydraulic kit
output
Thermostat
Thermostat
heat input
input
Commun
Summer
Winter
Thermostat
Summer /
Summer /
cool input
winter switch
winter switch
Geothermal OR Air source
Setting the comfort temperature in heating mode
Enter your desired setting using the + or - buttons.
Press OK to confirm and move on to menu CF04
With thermostatic valve electric heating or hot water heaters,
the Comfort temperature can be provided by adjusting the ther-
mostat of each radiator. In this case, only the Setback and Frost
Protection temperatures are set by the TYBOX.
Cooling function
If you have a reversible heating / cooling system, change the
setting on the CF04 menu to equal 1. You are now authorised to
switch the Tybox between heating and cooling modes. (see the
section on "Changing the heating / cooling mode")
7 - Activation
Turn the selector
dial to the position
The day numbers flash.
Days (1: Monday... 7: Sunday)
N
L
Hours
Minutes
• Press + or - to set the day, then OK
to confirm and go to the next setting.
Repeat these steps to set the hours
and minutes.
To exit the "time setting" mode,
turn the selector dial.
Comfort temperature set by the TYBOX
Comfort temperatures set by each radiator
or convector. In this option the screen
displays ConF.
Up to 7 home automation products can be associated with the RF 640 receiver.
• Intruder detector: open window = Frost Protection heating
• Telephone transmitter or telephone remote control: remote control of the installation
(heating, home control system)
• Alarm control unit: surveillance alarm = Setback heating
To link the receiver to a home control system product, the receiver must be switched into
linking mode. Press and hold the
Confirm the selection of the home control system product:
• door/window magnetic contact and telephone transmitter: quick press on the Test button
• telephone remote control: press the
• alarm control unit: in Maintenance mode, press on the test button
Radio configuration.
Your appliances are delivered linked and ready to be installed,
If you wish to cancel the linking of the receiver with the thermostat, press and hold the
receiver button for 30 seconds until the LED is no longer flashing. To relink the TYBOX 610
RF with the receiver, press and hold the receiver button for 5 seconds until the OK LED
flashes rapidly.
9 - Restoring factory settings
You can execute a general reset command to return to the factory settings:
- the default configuration settings
- the default set-point temperatures, Heating Mode - Comfort: 19°C, Setback: 16°C
Cooling mode - Comfort: 23°C, Setback: 28°C
- the default schedule (Comfort mode from 6am to 11pm).
Turn the selector dial to the position
Press the left button for 10 seconds.
Press OK to confirm or C to cancel.
Return to the shutdown mode display.
8 - Configuration
To access the configuration menus,
turn the selector dial to the position marked
Unit reference
Unit version
number
(e.g.: 1.00)
Correcting the temperature measured
Correction possible from -4°C to + 4°C in
increments of 0.1°C. Press the + or - buttons
to make changes, and confirm with the OK
button to move on to the next setting
IMPORTANT: In order to change this setting, the unit has
to have been running for at least 2 hours beforehand.
If there is a difference between the actual temperature
(taken with a thermometer) and the temperature measured
and displayed by the unit, the CF01 function can be used
to compensate for the difference by adjusting the sensor's
readings.
Cooling function not authorised
Cooling function authorised.
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF05
Switching the value on menu CF04 to 0 is only possible when the
TYBOX is in heating mode
Circulator pump anti-seizing
If your thermostat controls a circulator pump, set the value of the
CF05 menu to equal 1.
Anti-seizing off
Anti-seizing enabled (circulator pump
operates for 1 minute every 24 hours)
Enter your desired setting using the + or - buttons
Press OK to confirm and move on to menu CF06
non surveillance alarm = Comfort heating
button for 5 seconds until the OK LED flashes.
button
10 seconds
Cancel
The reference num-
ber of your device is
displayed as well as
the version number
Press OK to access
menu CF01
Confirmation