Parameter
Certs Path
Ping Payload
Ping Timeout ms
Ping Delay ms

Logon Options

Note:
Tap the Commit button to save changes. If this panel is closed before tapping the Commit button, changes are not
saved!
Logon Options
This option is only available on devices with a Windows XP Professional or Windows Embedded Standard operating system.
There are two options available, a
802.1x authentication and
If either option is enabled, the credentials entered here take precedence over any credentials entered on the
To use either option, select Logon Options from the Property list which activates the Logon Options button.
Default
A valid directory path, of up to 64 characters, where WPA Certificate
Authority and User Certificates are stored on the mobile device when not
using the Windows certificates store. Ensure the Windows folder path exists
before assigning the path in this parameter. See
certificates
on obtaining CA and User Certificates. This value is masked when the
Admin is logged out.
Options are: none.
The complete path is C:\Program Files\Summit\certs
Maximum amount of data to be transmitted on a ping.
32 bytes
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.
The amount of time, in milliseconds, that a device will be continuously
pinged. The Stop Ping button can be tapped to end the ping process ahead of
5000
the ping timeout.
Options are: Any number between 0 and 30000 ms.
The amount of time, in milliseconds, between each ping after a Start Ping
button tap.
1000
Options are: Any number between 0 and 30000 ms.
SCU
Use SCU or Windows login credentials.
single signon
which uses the Windows username and password as the credentials for
pre-logon
which uses saved credentials for 802.1x authentication before Windows logon.
Function
Certificates
More
info.
for instructions