UPS

When the Thor VM2 is operating on the UPS timeouts for any of the power schemes, the Thor VM2 behavior is described
below.

Thor VM2 is Off

Conditions
The Thor VM2 is Off and the power button is pressed the Thor VM2 and both the following conditions are met:
UPS power is over 10% capacity
l
CPU temperature is over 20ºC
l
Result
The Thor VM2 boots and follows the selected power scheme's Running on Batteries timeouts with power management timers
reset at boot up.
Conditions
The Thor VM2 is Off and the power button is pressed the Thor VM2 and at least one of the following conditions are met:
UPS power is under 10% capacity
l
CPU temperature is under 20ºC
l
Results
The Thor VM2 remains Off.

Thor VM2 is On

Conditions
The Thor VM2 is On and external power is removed, such as:
Thor VM2 is removed from a powered Dock (Dock power switch On)
l
Thor VM2 is mounted to a Dock and truck power is removed from the Dock
l
Thor VM2 is mounted to a Dock and the Dock power switch is turned Off
l
Result
The Thor VM2 boots and follows the selected power scheme's Running on Batteries timeouts with power management timers
reset at the time of power removal. UPS charging is disabled.
3-31