Data Field Display
ZONE SOUNDS AND TIMING (631– 639)
31 31 31 31
SINGLE ALARM
SINGLE
ALARM SND
SND
SINGLE
SINGLE
ALARM
ALARM
SND
SND
32 32 32 32
FIRE
FIRE SND
SND TIMEOUT
TIMEOUT
FIRE
FIRE
SND
SND
TIMEOUT
TIMEOUT
33 33 33 33
ALRM
ALRM SND
SND TIMEOUT
TIMEOUT
ALRM
ALRM
SND
SND
TIMEOUT
TIMEOUT
34 34 34 34
EXIT DELAY
EXIT
DELAY TIME
TIME
EXIT
EXIT
DELAY
DELAY
TIME
TIME
35 35 35 35
ENTRY DELAY
ENTRY
ENTRY
ENTRY
DELAY 1 1 1 1
DELAY
DELAY
36 36 36 36
ENTRY DELAY
ENTRY
ENTRY
ENTRY
DELAY
DELAY
DELAY 2 2 2 2
38 38 38 38
CON
CON
CON
CONF F F F ARM
ARM
ARM ING
ARM
ING
ING
ING DING
DING
DING
DING
† Entering a number other than the one specified may give unpredictable results.
Function& Programming Options
Single Alarm Sounding/Zone
† [0]
0 = Alarm Sounding Per Zone will be the same as the Swinger Shutdown" set in field *92;
1 = yes, limit once per arming period (also applies to long range radio output if "0" is
selected in 691 field)
Sounder Timeout
† [0]
0=timeout; 1=no timeout
Alarm Bell Timeout
† [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
Exit Delay
|
† [60]
45-96 = exit delay time (in seconds)
97 = 120 seconds
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value "60", which is displayed on the keypad, and advances to
the next field.
SIA: Must be set to a minimum of 45 seconds.
Entry Delay 1 (zone type 01)
|
† [30]
30-96 = entry delay 1 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value "30", which is displayed on the keypad, and advances to
the next field.
The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 entered in
SIA:
Field *35 and the burglary abort window entered in *50 should not exceed 1 minute.
Entry Delay 2 (zone type 02)
|
† [30]
30-96 = entry delay 2 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value "30", which is displayed on the keypad, and advances to
the next field.
SIA:
The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 2 entered in
Field *36 and the burglary abort window entered in *50 should not exceed 1 minute.
Confirmation of Arming Ding
Note: Confirmation ding only sounds when Safewatch QuickConnect Plus is Armed Away or disarmed
after being Armed Away. If Safewatch QuickConnect Plus is armed by RF button (key fob), a
confirmation ding occurs immediately after arming regardless of field
QuickConnect Plus is disarmed by RF button (key fob), additional disarming confirmation ding occurs
immediately after disarming and is longer than arming confirmation ding.
† [0]
0 =
no arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad or RF
;
keypad
1 = arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad
or RF keypad; 2 = arming confirmation ding after arming from RF keypad only
[ ] = Programmed Table 1 Default Values
UL installations = 1 (4 min) minimum
- 4 -
UL installations = 0
UL installations = 60 seconds max.
UL installations = 45 seconds max.
UL installations = 45 seconds max.