HEATSTRIP THH 1500 Installation, Operation & Maintenance Manual

HEATSTRIP THH 1500 Installation, Operation & Maintenance Manual

Heatstrip thh 1500; thh 2400; thh 3200; thh 1500ss; thh 2400ss; thh 3200ss electric radiant outdoor heater

Advertisement

Quick Links

Electric Radiant Outdoor Heater
Installation, Operation & Maintenance Manual
EUROPE / UNITED KINGDOM - ENGLISH
Models
THH 1500, THH 1500SS
THH 2400, THH 2400SS
THH 3200, THH 3200SS
Note: THH series HEATSTRIPS have an IPX5 rating for protection against water ingress. Prior to
installing and operating the heater, read these instructions carefully and retain for future reference.
Preparation
1.
The THH Series HEATSTRIPS are high intensity Radiant Strip Heaters designed for Domestic /
Commercial heating applications within indoor or outdoor undercover areas, and should not be
used for any other purpose.
2.
Before commencing installation, make sure the electrical supply voltage is the same as that
shown on the rating plate of the heater.
3.
The heater is fi tted with a length of fl exible cable for electrical connection. The heater should
be connected as a fi xed installation by a licensed electrical person, according to the relevant
electrical standards.
4.
All pole disconnection from the supply mains must be provided in fi xed wiring in accordance with
the wiring rules.
5.
This appliance must be earthed.
6.
The heater is required to be fi tted with an "ON/OFF isolation switch and can also be controlled
via thermostat, timer or dimmer type control. A wall switch should be installed on fi xed wire
installations. Optional connection to a R.C.D is recommended.
7.
If the heater or supply lead is damaged, the appliance must be returned to the distributor /
manufacturer for repair.

Installation Location

*
For both wall and ceiling mounting, the lowest part of the heater must be located a minimum of
2100mm above fl oor level.
*
The heater must not be closer than 300mm to adjacent walls, with a minimum of 60mm
between back of heater and any surface.
*
Allow 1000mm from the bottom of the heater to any surface below.
*
Do not allow thermal insulation, cables, fl ammable materials or any other items to come into
contact with any surface of the heater; purpose design brackets excluded.
*
The heater must not be located immediately below a socket outlet.
*
If installed in wet areas, the heater must be installed so that switches and other controls cannot
be touched by persons in the bath or shower.
Watts
Dimensions
1550
850 x 170 x 40mm
2500
1330 x 170 x 40mm
3350
1770 x 170 x 40mm
Ratings
230V 50Hz a.c
230V 50Hz a.c
230V 50Hz a.c
ENGLISH 1

Advertisement

loading

Summary of Contents for HEATSTRIP THH 1500

  • Page 1: Installation Location

    Electric Radiant Outdoor Heater Installation, Operation & Maintenance Manual EUROPE / UNITED KINGDOM - ENGLISH Models Watts Dimensions Ratings THH 1500, THH 1500SS 1550 850 x 170 x 40mm 230V 50Hz a.c THH 2400, THH 2400SS 2500 1330 x 170 x 40mm 230V 50Hz a.c...
  • Page 2: Mounting Instructions

    The power cable must be at the lower end of the heater if the heater is installed at an angle. Dim “A” Self Tapping Screw M5 Hex Nut M5 Machine Thread Screw Model DIM “A” THH 1500 300mm THH 2400 600mm THH 3200 900mm Operation Instructions [To be kept by the user of this appliance] The heater is required to be fi...
  • Page 3 Even in city locations, pollution in the air can also contaminate surfaces and will affect the ability of the coatings and material of your THH HEATSTRIP to protect from rust and stains. This applies to both the painted and stainlesss steel models. As the THH HEATSTRIP has a protection rating for water ingress of IPX-5, they can be safely washed and cleaned with water.

This manual is also suitable for:

Thh 2400Thh 3200Thh 1500ssThh 2400ssThh 3200ss