Fig. 6.2
Important !
Use two wrenches to tighten the connection.
Note: take care not to overtighten the coni-
cal adaptor, as doing so may crack the test
point adaptor.
Interpose the
supplied gasket.
Important !
Use two wrenches to
tighten the connection.
30
Installing the Test Point Adaptor
Appliance
gas inlet pipe
Nipple
Gasket
Conical adaptor
Test point adaptor
Test point
LOCK
Arrow
Fig. 6.3
LOCK
Fig. 6.4
G 1/2 cylindrical
(ISO 228-1) male
G 1/2 cylindrical
(ISO 228-1) female
R 1/2 conical
(ISO 7-1) male
Rc 1/2 conical
(ISO 7-1) female
Rc 1/2 conical
(ISO 7-1) female
Using a suitable leak detection fluid so-
lution (e.g. Rocol) check each gas con-
nection one at a time by brushing the
solution over the connection.
The presence of bubbles will indicate a
leak.
If there is a leak, tighten the fitting and
then recheck for leaks.
IMPORTANT! Do not use a naked flame
to test for leaks.
OK
Fig. 6.5