Mantel Requirements; Combustible Mantels; Examples; Non-Combustible Mantels - Travis Industries 864 See Through GS2 Installation Manual

Table of Contents

Advertisement

Mantel Requirements

Combustible Mantels

Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured from the
face of the fireplace) must fall in the shaded portion of the table.
Any material that protrudes more than 3/4" (19mm) from the non-combustible facing is considered a mantel
and must meet the mantel requirements.
Maximum Mantel Depth (b)
(457mm) 18+"
(432mm) 17"
(406mm) 16"
(381mm) 15"
(356mm) 14"
(330mm) 13"
(305mm) 12"
(279mm) 11"
Mantel
(254mm) 10"
Height
(229mm) 9"
Above
(203mm) 8"
Face (a)
(178mm) 7"
(152mm) 6"
(127mm) 5"
(102mm) 4"
(76mm) 3"
(51mm) 2"
(25mm) 1"
0"

Examples:

- If you wish to have an 8" (203mm) deep mantel, it must be at least 6-3/4" (171mm) above the fireplace face (44-3/4", 1137mm above the base).
- If you wish to have a mantel 8" (203mm) above the fireplace face, it must be no deeper than 9" (229mm).

Non-Combustible Mantels

Non-combustible mantels must meet the clearances listed for combustible mantels. However, if you do wish to
reduce the clearances by using a non-combustible mantel, the following requirements must be met:
Non-combustible mantel
and facing must extend
from the top of the
appliance to the top
surface of the mantel.
A non-combustible
header must be used
(metal stud).
© Travis Industries
Installation
(for qualified installers only)
Combustible Mantel
a
36-3/4"
933mm
Non-Combustible Framing (metal studs)
must be used for the header.
4121105
b
Base of the Fireplace
SIDE OF FIREPLACE
37
Combustible mantel columns (legs) that protrude
more than 3/4" (20mm) from the glass frame
must meet the sidewall clearance (1" (25mm)
from fireplace, 3-1/4" (83mm) from the glass
frame). If they protrude 3/4" (20mm) or less, they
must meet the facing clearance 2-1/4" (57mm)
from the glass frame.
Non-combustible mantel columns do not have a
minimum clearance.
Drywall
Non-Combustible Mantel
Non-Combustible Facing
100-01303

Advertisement

Table of Contents
loading

This manual is also suitable for:

864

Table of Contents