Symptom
The unit does not work, no light
No response to the DMX con‐
troller
No response to the remote con‐
trol
LED Flood Panel 150
Remedy
Check the mains connection and the main fuse.
1. If the unit is in DMX mode and a DMX controller is
connected and turned on, the LED (6) behind the first
digit of the display will flash. If it doesn't, no valid DMX
signal is received. Check that the DMX controller is
switched on. Check the DMX connectors and cables for
proper connection.
2. If the display is not flashing but there is still no
response, check the address settings and the DMX
polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside
to high voltage cables that may cause damage or inter‐
ference to DMX interface circuits.
1. Try using the remote control at a different angle to the
IR sensor on the front panel of the device.