  • Page 1 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 2 Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 Internet: www.thomann.de 13.07.2022, ID: 253406 (V6)
  • Page 3: Table Of Contents

    Connections and operating elements................... 21 Operating..............................26 7.1 Starting the device........................... 26 7.2 Main menu............................26 7.3 Menu overview..........................32 Technical specifications........................39 Plug and connection assignments....................41 Troubleshooting............................42 Cleaning............................... 44 Protecting the environment......................45 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 4 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 5: General Information

    Our products and user manuals are subject to a process of continuous development. We there‐ fore reserve the right to make changes without notice. Please refer to the latest version of the user manual which is ready for download under www.thomann.de. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 6: Further Information

    Personal consultation For personal consultation please contact our technical hotline. If you have any problems with the device the customer service will Service gladly assist you. 1.2 Notational conventions This manual uses the following notational conventions: LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 7: Symbols And Signal Words

    Ä ‘Cross-references’ on page 7. 1.3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 8 Warning signs Type of danger Warning – high-voltage. Warning – dangerous optical radiation. Warning – suspended load. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 9 General information Warning signs Type of danger Warning – danger zone. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 10: Safety Instructions

    Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke! Never let children unattended use electrical devices. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 11 Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights. NOTICE! Risk of fire Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 12 Possible damage due to installation of a wrong fuse The use of different types of fuses can cause serious damage to the unit. Fire hazard! Only fuses of the same type may be used. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 13 Possible damage by leaking batteries Leaking batteries can cause permanent damage to the device. Take batteries out of the device if it is not going to be used for a longer period. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 14: Features

    For technological reasons, the light output of LEDs decreases over their lifetime. This effect increases with higher operating temperature. You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 15: Installation

    Risk of overheating The distance between light output and the illuminated surface must be more than 1.5 m (19.7in). Provide sufficient ventilation. The ambient temperature must always be below 40 °C (104 °F). LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 16 The safety cable must be routed through the safety eyelet on the rear side ( Ä Chapter 6 ‘Con‐ nections and operating elements’ on page 21). LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 17 Installation Please note that this device must not be connected to a dimmer. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 18 Possible damage by leaking batteries Leaking batteries can cause permanent damage to the device. Take batteries out of the device if it is not going to be used for a longer period. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 19: Starting Up

    Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W). LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 20 Connect the DMX output of the master device to the DMX input of the first slave device. Then connect the DMX output of the first slave device to the DMX input of the second slave device and so on. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 21: Connections And Operating Elements

    2 [Mode] | calls the main menu or a submenu. 3 [Setup] | confirms a selected value. 4, 5 [Up], [Down] | increase / decrease the displayed value by one. Mode Setup Down & LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 22 Connections and operating elements Rear panel DMX In DMX Out Power Out Power In LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 23 Infrared sensor for the remote The infrared sensor for the optionally available IR remote control signals is located on the front control (optional) panel of the device. Make sure it is not obstructed. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 24 Infrared remote control (item no. 354223, optionally avail‐ Since the universal remote control can be used for several device types, some buttons able) may not be assigned and therefore have no function. & ö LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 25 9 [Dimming] | activates the dimming function for fixed colours. Set the value for each fixed colour using [+] and [–]. 10 [0 … 9] | numeric buttons for direct selection of a fixed colour. 11 [R], [G], [B], [A], [W] | buttons to select the colour shade in dimmer mode. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 26: Operating

    If you don't press any button for about 20 seconds, the unit returns to the previously selected mode. The set values are retained even when the device is disconnected from the mains power supply. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 27 This setting is only relevant when the device is controlled via DMX. When the display shows the desired value, press [Setup] to confirm the selection and then [Mode] to return to the parent menu. To return to the parent menu without making changes, press [Mode]. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 28 Slow transition bright / dark, red Pr.09 Slow transition bright / dark, green Pr.10 Slow transition bright / dark, blue The auto show can only be activated on the device that works as master. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 29 When the display shows the desired value, press [Setup] to confirm the selection and then [Mode] to return to the parent menu. To return to the parent menu without making changes, press [Mode]. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 30 Confirm again with [Setup]. In the following menu, you can use [Up] and [Down] buttons to set the strobe speed for the various hues in a range from ‘FS00’ to ‘FS99’ . LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 31 Press [Mode] repeatedly until the display shows ‘SU xx’ . This activates the sound controlled automatic show. Press [Setup] and use [Up] and [Down] to adjust the sensitivity for the sound control in a range from ‘SU.00’ to ‘SU.31’ . LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 32: Menu Overview

    7.3 Menu overview SU.xx SLAv d.xxx AUTO Pr.xx SU.00 ... SU.31 d.001 ... d.512 SP.01 ... SP99, SP.FL Pr.01 ... Pr.10 d-P1, d-P2, d-P3 FS00 ... FS99 Id.01 ... Id.66 Fd00 ... Fd99 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 33 Function 0…255 Dimmer (0 % to 100 %) 0…255 Intensity red (0 % to 100 %) 0…255 Intensity green (0 % to 100 %) 0…255 Intensity blue (0 % to 100 %) LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 34 Red: 255, Green: 50 18…26 Red: 255, Green: 150 27…35 Red: 255, Green: 255 36…44 Red: 200, Green: 255 45…53 Red: 100, Green: 255 54…62 Red: 40, Green: 255 63…71 Green: 255 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 35 Red: 150, Green: 50, Blue: 100 171…179 Red: 50, Green: 180, Blue: 220 180…188 Red: 50, Green: 220, Blue: 100 189…197 Red: 150, Green: 220 198…206 Red: 150, Blue: 220 207…215 Green: 180, Blue: 220 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 36 Intensity Green 0…255 (0 % to 100 %) Channel 6 = 1… Without function Channel 6 = 0 Intensity Blue 0…255 (0 % to 100 %) Channel 6 = 1… Without function 0…9 Without function LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 37 Pr.09 (slow transition bright / dark, green) 225…249 Pr.10 (slow transition bright / dark, blue) 250…255 Sound control Control of all devices that use the same DMX address 0…9 All IDs 10…19 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 38 Operating Channel Value Function 20…29 … 200…209 ID20 ID21 ID22 … ID66 0…250 Fast response faders 1, 2, 3 and 4 251…255 Delayed response faders 1, 2, 3 and 4 LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 39: Technical Specifications

    50/60 Hz Fuse 5 mm × 20 mm, 1 A, 250 V, slow-blow Battery of the remote control Lithium-ions button cell CR2025, 3 V Degree of protection IP20 Mounting options Hanging, standing LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 40 0 °C…40 °C Relative humidity 20 %…80 % (non-condensing) Further information Construction Flat PAR Colour mixture LED type x-in-1 Base housing Fanless Remote control Optionally available (item no. 354223) Wireless DMX Housing colour Black LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 41: Plug And Connection Assignments

    The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug. Configuration Ground, shielding Signal inverted (DMX–, ‘cold signal’) Signal (DMX+, ‘hot signal’) LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 42: Troubleshooting

    Never connect the DMX input or output to audio devices such as mixers or ampli‐ fiers. In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting: LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 43 DMX interface circuits. If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 44: Cleaning

    Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 45: Protecting The Environment

    Protect used lithium batteries against short circuits, for example by covering the poles with adhesive tape. Permanently built-in lithium batteries must be disposed of together with the device. Please inquire about an appropriate collection point. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 46 Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility. LED Flood TRI Panel 7x3W RGB LED Floodlight...
  • Page 48 Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de...