High-definition indoor fixed dome camera whith d/n (26 pages)
Summary of Contents for Siqura FD820M1(IR)-SFP
Page 1
FD820M1(IR)-SFP High-definition fixed dome camera with SFP interface...
Page 2
Any brand names mentioned in this manual are registered trademarks of their respective owners. Liability Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual. Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant product components, this manual may nonetheless contain errors and inaccuracies.
This manual is intended for technicians involved in the installation of FD820M1(IR)-SFP cameras. What you should already know To be able to install and connect the FD820M1(IR)-SFP properly, you should have adequate knowledge and skills in the following fields. ●...
Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of design, manufacture, and intended use of the module. Siqura assumes no liability for the customer's failure to comply with any of these safety requirements.
Page 6
Safety information Optical safety This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. This optical equipment contains Class 1M lasers or LEDs and has been designed and tested to meet IEC 60825-1:1993+A1+A2 and IEC 60825-2:2004 safety class 1M requirements.
European Union (EU) to enact the Directive on the Restriction of the use of certain Hazardous Substances (RoHS) (2002/95/EC). Siqura offers products that comply with the EU’s RoHS Directive. The full version of the Siqura RoHS statement can be viewed at www.siqura.com.
3.4 Dimensions......................11 Description The FD820M1(IR)-SFP camera is a compact camera with an easy setup design. Quad streams compression (H.264 Baseline / Main / High Profile + MJPEG) is supported for efficient bandwidth and storage management. For dark environments, the camera has incorporated WDR, 3DNR and Day/Night ICR technologies to capture clear images in low-light conditions.
Package contents Before you proceed, verify that the box contains the items listed here. If any item is missing or has defects, do not install or operate the product. Contact your supplier for assistance. FD820M1(IR)-SFP 3-Pin connector Conduit 2-Pin connector...
Connectors and cabling This chapter describes the buttons and connectors on the printed circuit board (PCB) of the FD820M1(IR)-SFP and gives instructions for connecting power, Ethernet, audio, and alarm I/O cables. In This Chapter 4.1 Connectors......................12 4.2 Connect power cabling...................13 4.3 Connect to network....................
Note: Insert the SD card into the Micro SD card slot before you power on the camera. If the camera is already powered on, reboot the camera after the SD card is inserted. Connect power cabling The FD820M1(IR)-SFP camera can be powered by 12 Vdc or 24 Vac (terminal block). To power on the camera ●...
A green link light indicates a good network connection. The orange activity light flashes to indicate network activity. Connect audio If microphones and speakers are configured to the network, the FD820M1(IR)-SFP can be used to provide a two-way audio channel. To connect audio ●...
Connectors and cabling Connect alarm I/O The camera equips one alarm input and one relay output for alarm application. To connect an alarm device ● Connect the alarm relay connectors to the terminal block on the back of the camera. For the location of this block and the alarm pin definition, see Connectors ( on page 12) and the figure below.
Hard ceiling installation The FD820M1(IR)-SFP can be installed directly on the ceiling. Note that the ceiling must have enough strength to support the IP camera. In This Chapter 5.1 Prepare the installation..................16 5.2 Install the camera....................16 Prepare the installation Items needed ●...
Page 17
Hard ceiling installation Step 2 Press both sides of the inner cover and remove it. Step 3 Loosen the two camera-fastening screws, and then detach the camera housing. Step 4 Choose a suitable conduit entry on the camera housing for cable connection. If you use the back conduit entry, open the conduit entry block (see figure on the right) with a coin, and then use it to close the side conduit...
Page 18
Hard ceiling installation Back conduit entry Step 6 Drill each hole slightly smaller than the supplied screw anchors at the marked locations. Then insert the anchors into the drilled holes. Step 7 Place the camera housing at the installation location and align the screw holes of the camera housing with the drilled holes.
Page 19
Hard ceiling installation Step 9 Thread the SFP cable and power cable through the conduit entry as shown in the figures on the right. If there are other cables, such as cables for alarm connections, also insert them through the conduit entry. Side conduit entry Back conduit entry Step 10...
Page 20
Adjust the Pan / Tilt / Spin holders of the camera to point the lens at a suitable position for the desired camera view. You can check the camera view in Siqura Viewer (for more information, see the User Manual). Note ●...
In This Chapter 6.1 Prepare the installation..................21 6.2 Install the cable gland................... 21 Prepare the installation Items needed ● FD820M1(IR)-SFP camera ● SFP Cable ● Power cable (supplied) ● 2-Pin terminal block for DC 12 V (supplied) ●...
Page 22
Cable gland installation Step 2 Loosen the thread-lock sealing nut from the gland body. Then thread the SFP cable and the power cable through the thread-lock sealing nut. Step 3 Run the cables through the gland body. Note The sealing rubber will be installed at a later stage.
Page 23
Cable gland installation Back conduit entry Step 6 Connect the cables to the camera body. Step 7 Place the camera body back onto the camera housing and tighten the camera-fastening screws indicated in the figure on the right. Step 8 Fasten the gland body to the side conduit entry / back conduit entry.
Page 24
Cable gland installation Step 9 Install the sealing rubber of the cable gland onto the cables (as shown on the right). Then push the sealing rubber into the gland body. Step 10 Fasten the thread-lock sealing nut to the gland body. Step 11 Using a hot glue gun, seal the end of the thread-lock sealing nut with hot glue.
7.2 Attach the camera to the mounting kit..............25 Prepare the installation Mounting kit package contents ● Mounting kit (x1) Items needed ● FD820M1(IR)-SFP camera ● SFP Cable ● Power cable (supplied) ● 2-Pin terminal block for DC 12 V (supplied) ●...
Page 26
Mounting kit installation Step 2 Press both sides of the inner cover and remove it. Step 3 Loosen the two camera-fastening screws, and then detach the camera housing. Step 4 Connect the power cable to the 2‑pin (DC 12 V) or 3-pin (AC 24 V) terminal block as applicable.
Page 27
Mounting kit installation Step 6 Connect the cables to the camera body. Step 7 Align the camera body with the tenon on the mounting kit. Then place the camera body on the mounting kit. Tighten the camera- fastening screws on the camera body. Adjust the lens as necessary, as described in Step 12 of Hard ceiling installation ( on page 16), and then place the inner cover back...
Standard/Compact pendant mounting The FD820M1(IR)-SFP can be mounted on the wall or on the mounting accessory with the standard/compact pendant mount. The subsections in this chapter introduce direct wall installation and mounting accessory installation. Refer to the section which describes the mounting method that you are going to apply.
Therefore, instructions for installing mounting accessories are not provided here. Before you start the installation, fix the mounting accessory to the chosen place first. 8.3.1 Prepare the installation Items needed ● FD820M1(IR)-SFP camera ● SFP Cable ● Power cable (supplied) ●...
Standard/Compact pendant mounting ● 3-Pin terminal block for AC 24 V (supplied) ● Mounting accessory Tools needed ● Tools for drilling ● Tools for screwing 8.3.2 Install the camera Step 1 Run the SFP cable and the power cable through the standard/compact pendant mount.
Page 32
Standard/Compact pendant mounting Step 3 Refer to step 1 ~ 7 of chapter Mounting kit installation ( on page 25) to attach the camera to the mounting kit. Step 4 After the camera is mounted to the mounting kit, fix the mounting kit with the camera to the pendant mount, and align the screw hole of the joint with the one on the pendant.
Index About this manual........4 Safety.............5 Attach the camera to the mounting kit..25 Safety information........5 Standard/Compact pendant mounting..28 Cable gland installation......21 Cautions..........7 Compliance..........8 Connect alarm I/O........15 Connect audio........14 Connect power cabling......13 Connect to network.........14 Connectors..........
Need help?
Do you have a question about the FD820M1(IR)-SFP and is the answer not in the manual?
Questions and answers