Removing/Fitting Pump; Gallon Ae); Removing/Fitting Non-Return Pipe (Attix 751-61/-71, 19 Gallon Ae) - Nilfisk-ALTO ATTIX 751-01/-11/-21 Repair Manual

Table of Contents

Advertisement

Nilfisk
ALTO
3.9 Removing/fitting pump (Attix 751-61/-71, Attix 19 Gallon AE)
3.10 Removing/fitting non-return pipe (Attix 751-61/-71, Attix 19 Gallon AE)
Attix7_ver.1.0_140105
Troubleshooting
1. Take the cleaner head
with the adapter ring off
the container, and lift the
container out of the base
frame..
2. Take out the C-coupling
(see 3.8/3, page 27).
Attix7 3668
E
Attix7 3664
3. Disassemble the plug
(1) of the pump (3), undo
the cable fixture (4) on the
container, pull the cable
through, and take out the
pump.
Fit in the reverse order.
1. Remove the pump (1)
(see 3.9, page 28).
2. Unscrew the non-return
pipe (2) from the threaded
fitting of the pump (1), and
remove it.
3. Fit in the reverse order.
Note:
The threaded fitting can
be sealed with normal
silicone.
29/59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents