Error code
Remote controller:
None
1. Applicable model
All models
2. Error detection method
3. Condition of Error displayed
4. Presumable cause
• Remote controller wire
breakage/short-circuit
• Defective remote controller
• Malfunction by noise
• Faulty indoor power PCB
• Broken harness
• Faulty indoor control PCB
Note:
LED
Green
Red
Keeps flashing Stays OFF
Indoor
Stays OFF
Outdoor
5. Troubleshooting
Diagnosis
loose connection of remote
controller wires?
controller wire broken or
Disconnect remote
controller wires.
higher detected between X-Y
of indoor unit terminal
between - of
84
-
Content
Power supply system error
(Power supply to remote controller)
Isn't there any
YES
NO
Isn't remote
YES
short-circuited?
NO
Is DC15V or
YES
block?
NO
Is DC180V
NO
CNW2?
YES
-
'10 • SCM-SM-094
Countermeasure
Correct.
Replace wires.
Replace remote controller.
Defective indoor power
PCB Replace.
Defective indoor control
PCB Replace.