Mitsubishi Heavy Industries SRK20ZJX-S Service Manual page 70

Hide thumbs Also See for SRK20ZJX-S:
Table of Contents

Advertisement

●DIP switch setting list
Switches
Address No. setting at plural indoor units control by 1 R/C
SW2
SW6-1
SW6-2
Model selection
SW6-3
SW6-4
Test run, Drain motor
SW7-1
SW7-2
Reserved
Powerful mode
SW7-3
Reserved
SW7-4
JSL1
Superlink terminal spare
Table 1: Indoor unit model selection with SW6-1-SW6-4
0: OFF
25VD
SW6-1
SW6-2
SW6-3
SW6-4
Description
Normal * /Test run
Valid*/Invalid
Normal * /switch to spare
* Default setting
1:ON
35VD
50VD
60VD
1
0
1
1
0
1
0
1
0
0
1
1
0
0
0
0
Default setting
0
As per model
Normal
OFF
OFF
Valid
ON
OFF
With
69
-
-
'10 • SCM-SM-094
Remarks
0-F
See table 1
keep OFF
keep OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents