CHAP. XI
operation of appliances
ComBI trumA D4 / D6 / D6E
n
Shutting down:
n
Shut the heater down with the rotary
switch (position f). The green LED (b)
goes out.
SIf the green LED (b) blinks
i
after the power is switched off,
this means that a shutdown timeout
to lower the unit temperature is
running. This stops after a few minutes
and the green LED (b) goes out.
Always drain the heater if there is a
risk of frost!
Maintenance :
n
It is mandatory to use original Truma
parts for all maintenance or repair
work.
The water reservoir is made of steel
used for alimentary applications.
To protect the apparatus from
colonisation by micro-organisms, use
chemical methods to remove biofilms,
deposits and scale. To avoid damage
to the apparatus, use only non-
chlorinecontaining products.
46
If
necessary,
regularly
the water in the water heater to
70° C to maintain the effectiveness of
the chemical method for combating
micro-organisms inside the apparatus.
Adjust the rotating switch on the
thermostat control to position "c"
(summer mode, 60° C). The green (b)
and the yellow (g) LEDs will light up.
When the water in the water
i
heater reaches a temperature
of 60° C, the burner will stop and
the yellow LED (g) will turn off. The
apparatus should remain lighted for
at least 30 minutes and no hot water
should be used. Residual heat from the
thermal exchanger will heat the water
to a temperature of 70° C.
reheat
Fuses :
n
The fuses are in the electronic control
unit underneath the connector cover.
Replace defective uses with exactly the
same fuses only.
Unit fuse:
10 A - delayed action - (T 10 A)
Burner fuse:
20 A - delayed action - 6.3 x 32 mm
?