Ref#
Wire Color
1
Black
2
Brown
3
Red
4
Orange
5
Yellow
6
Green
7
Blue
8
Purple
9
Grey
10
White
11
Pink
12
Light Blue
R S T5. 6 & R CT 7 . 6 S e a r s S e r v i c e M a n u a l 2 0 0 7
C o n s o l e C a b le V o lt a g e C h a r t ( D C V o l t s)
Function
Voltage / Ohm Readings
Incline VCC
+2.5 vdc constant
Incline Pot
+2.5 vdc at 0.0% incline, +0.5 vdc at max incline
Voltage changes with each change in incline
Incline GND
n/a ground
Digital GND
n/a ground
Digital GND
n/a ground
RPM
When speed sensor aligned to magnet: short, 0.0 vdc
When sensor not aligned: open, +5.0vdc
Power Voltage(to UCB)
+15 vdc constant Range = +15.0 to +17.0 vdc
Power Voltage(to UCB)
+15 vdc constant Range = +15.0 to +17.0 vdc
Speed Command
0.0 vdc before started, +0.5 vdc at 0.5 mph, +4 vdc
(PWM)
at 10 mph. Voltage changes as speed changes
Drive Motor Relay
+4.3 vdc before started
0.0 vdc after started
Incline Down
0.0 vdc before started, 0.0 vdc while inclining, +1.9
vdc while declining. Voltage constant while inclining/
declining
Incline Up
0.0 vdc before started, +1.9 vdc while inclining, 0.0
vdc while declining. Voltage constant while inclining/
declining
B1: Incline VCC
B2: Incline Pot
B3: Incline GND
B4: Digital GND
B5: Digital GND
B6: RPM
B7: Power Voltage (to UCB)
B8: Power Voltage (to UCB)
B9: Speed Command (PWM)
B10: Drive Motor Relay
B11: Incline Down
B12: Incline Up
rst 5.6 & rct 7.6 service manual 2007_rev1.0 | 23