PAMS Technical Documentation
RX Calibration... command
Activation
Alt, T, R
Starts RX calibration.
Next automatic selections are made when this tuning function is acti-
vated:
The measurement is started automatically when RX calibration is entered.
The measurement is done in five steps:
1. The user is requested to put signal generator to high input level (read
from .INI file).
2. Measurement with high input level is executed
3. The user is requested to put signal generator to low input level (read
from .INI file).
4. Measurement with low input level is executed
5. The RX Calibration dialog will be updated when previous steps are
done.
Issue 4 02/2002
Status Bar Text
Open RX Calibration dialog box
Phone is set to local mode
Update RF information window
E Nokia Mobile Phones Ltd.
NSM–3/3D
Service Software Instructions