Installation Accessories - Bosch MIC440 Installation And Operation Manual

Explosion protected cctv camera system
Hide thumbs Also See for MIC440:
Table of Contents

Advertisement

Available languages

Available languages

MIC440 Explosion Protected CCTV Camera System| Installation and Operation Manual

Installation Accessories

CAUTION: Ensure all local safety codes are observed when
installing this product; ensure a strong safety chain is used to
secure the MIC440 camera to prevent any danger of dropping
the product during installation. Particular care should be taken
with MIC440 models due to the additional weight.
The MIC440 Camera has been designed to be easily installed on a variety of
common fittings. The MIC440 comes with an integrated Deep Conduit Adaptor
with an M20 threaded hole for a suitable Exd cable gland (Not supplied).
The MIC440 cameras can be mounted on lamp post column/scaffolding pole or
similar using the Pole Mount Bracket (MIC-PMB) however users should be aware
that lamp posts can often be subject to movement and are not suitable platforms in
all conditions or for all applications.
For mounting directly onto buildings Bosch Security Systems manufacture a range
of brackets suitable for all typical building installations for upright (90°) or Inverted
camera positions, examples are shown below.
MIC-CMB
-
Corner Mount Bracket
MIC-WMB
-
Wall Mount Bracket
MIC-SCA
-
Shallow Conduit Adaptor
MIC-DCA
-
Deep Conduit Adaptor (Included)
MIC-PMB
-
Pole Mount Bracket
CAUTION: For additional protection in hazardous area
installations suitable flexible conduit can be used externally for
the composite cable run to connect the power supply to the
Exd Cable Gland (Not supplied) in the MIC440 Deep Conduit
Adaptor