Video; Sense Input - Elan M86A Installation Manual

Multi-room audio controller
Table of Contents

Advertisement

E L A N
Symptom
Possible Cause
Incorrect source
1.
playing on speakers
2.
Symptom
Possible Cause
Video not switching
1.
when using V8
Video Router
2.
3.
Video switches but
1.
is incorrect
2.
3.
Symptom
Possible Cause
Conditional
1.
commands / Event
Maps not working
2.
properly
3.
4.
© ELAN 2010 | All rights reserved.
Audio (Continued)
Source connected to wrong input of
M86A.
Speakers connected to incorrect
speaker outputs.

Video

VIANet connection faulty or not
connected.
Incorrect programming
V8 unit ID not set correctly.
Source video not connected to the
correct input.
Video Outputs of the switcher
connected to the wrong TS7s /
monitors.
V8 unit ID set incorrectly.

Sense Input

Conditional programming / Event
Map incorrect
Sensor faulty or not connected
properly
Incorrect Sensor being used
VIANet connection not made / faulty
Solution
1.
Verify / correct input connections.
2.
Verify / correct speaker connections.
Solution
1.
Connect Cat5 using VIANet wiring color code. Verify
connections.
2.
Verify / correct programming.
3.
Set unit ID correctly.
1.
Connect source video correctly.
2.
Connect Video Outputs to the correct TS7s / monitors.
3.
Set unit ID correctly.
Solution
1.
Verify / correct programming in the ELAN
configuration software
2.
Verify / correct Sensor operation and connection.
3.
Use correct sensor
4.
Verify / correct VIANet connection
M86A
INSTALLATION MANUAL
Page 35

Hide quick links:

Advertisement

Table of Contents
loading