Bellfires DERBY LARGE 3 CF Installation Instructions Manual page 36

Gas fire with closed combustion system
Table of Contents

Advertisement

Bellfi res
1.7.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight
using soapy water or a leak tester.
1.7.5 Positioning the ceramic log set or marble pebbles
The appliance can be supplied with:
• Ceramic log set + embers
• Marble pebbles white (small, white marble stones)
• Marble pebbles grey (small, grey marble stones)
Important:
• Carefully place the chips of wood/embers/vermiculite granules/
log set or marble pebbles, on and around the main burner
according to the directions in this chapter.
• Do not place any chips of wood/embers/vermiculite granules/
log set or marble pebbles against the pilot light burner.
For that reason, the main burner has a protective pilot-light cowl.
Never remove this cowl! Make sure that the pilot fl ame can burn
at all times freely over the main burner. Only in this way is
proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Make sure that all burner orifi ces remains free at all times!
• The burner bed (with chips of wood/embers/vermiculite
granules) and the positioning of the logs or marble pebbles
must not be changed.
• Only use those items supplied! These been rigorously
checked and the quantities adapted to the appliance.
• Replacement parts, including the ceramic mat are available
from your dealer.
• Fitting may only be carried out by a qualifi ed person.
Remove the glass according to the instructions in chapter 4; DISMANTLING /
ASSEMBLING OF THE GLASS.
58