Borro moluptat rae moditaspis Borro moluptat rae moditaspis Printed in U.S.A. 09.13...
Page 2
In order to get the most out of your MDHearingAid AIR, please read this User Manual in its entirety. ® Your satisfaction with hearing aids depends on both the type and degree of your hearing loss as well as your expectations.
(below 1000 Hz); however, the majority of hearing loss is in the higher The MDHearingAid AIR has been rigorously tested by leaders in the hearing ® frequencies (1000-4000 Hz), those most related to loss field (ENT Physicians and Audiologists) who have unanimously agreed the human voice.
Types: Open-Fit or Closed Ear Dome Volume Dial Body Sizes: 6 mm – 15 mm (on/off switch) Step 2: Attach AIR Tubing Base Program Button to Hearing Aid Body Step 3: Insert Battery Battery Step 4: Place Hearing Aid Behind Ear...
Best for individuals who have tubing length. (See separate package high frequency loss and do not located under tray.) Right and Left ear AIR Tubing Cleaning Tool require high volume. • For Right ear, use the tubing...
Pull the outer ear upward and backward. for fitting Right ear. Use Left Tubing With your other hand, hold the AIR Tubing (with Ear (Blue lettering) for fitting Left ear. Dome attached) at the junction of the Stabilizer Bar.
Step 2 Step 3 Step 2: Attach AIR Tubing Base to Hearing Aid Body Step 3: Insert Battery To power up your Hearing Aid, please insert a) Hold the top of the AIR Tubing Base one of the included size 13 batteries.
Page 9
Volume Dial upward, past the click. b) Place the Hearing Aid Body behind the ear so the curve of the AIR Tubing rests • To turn the Hearing Aid off, turn the comfortably on the top of ear in front of Volume Dial downward until you feel a click.
Page 10
Selecting a Sound Processing Program Program Best For Description Indicator The MDHearingAid AIR has four Sound Processing Programs to address the ® 1. Normal Home, watching TV, Increases sound in 1 Tone most common hearing loss environments. Try the different programs in each Quiet Mode time with family.
These phones will work with programs 1-3. To activate the Telecoil mode (Program 4) The speaker function on your phone also works well with your MDHearingAid ® Push the Program Button until you hear four tones. In Telecoil mode, the Hearing Aids.
Getting the Most from Your Hearing Aid Key #1 — Patience Your satisfaction with Hearing Aids depends on the type and degree of your New hearing aids can be a big adjustment. Your brain has to re-learn how hearing loss and your expectations. No hearing aids will restore the normal to hear and listen.
Using Hearing Aids takes practice and patience. Some If you have hearing loss in both ears and only ordered one Hearing Aid, we people adjust very quickly and most adapt within a few strongly encourage you to use the enclosed coupon for a discount on a weeks. Please do not give up prematurely. A whole new second MDHearingAid AIR. As always, you will receive a 45-day risk-free ® world of sound awaits you. trial with our money-back guarantee.
Low Battery Warning Battery Type: The MDHearingAid AIR uses size ® When the battery voltage nears the end of its life, the MDHearingAid AIR will ® 13/13A zinc-air batteries. provide a low battery warning signal. The initial warning will be three sets of double beeps.
® Earwax can clog up AIR Tubing. For best results, it may be beneficial to clean 3. Check that the Ear Dome or AIR Tubing is not blocked by earwax. your ears with an over-the-counter ear wash kit or visit your physician.
• Try reinserting the Ear Dome • Clean any wax from the AIR into ear so it fits better. If that For optimal performance, the Hearing Aid Ear Domes and AIR Tubing that may be interfering doesn't work, try a different Tubing should be replaced every 3-6 months.
Page 17
• Make sure the Hearing Aid is on. • Reposition the AIR Tubing and humid environment or subject AIR Tubing for wax or for any The Volume Dial should be set Ear Dome in your ear canal. to sweat, moisture may clog signs of wear.
Replacement of AIR Tubing & Ear Domes Warranty & Repair The MDHearingAid AIR is covered against defects in materials and ® For OPTIMAL PERFORMANCE, the AIR Tubing workmanship for 90 days from the date you receive your order. If our...
If, after 21 days of using the MDHearingAid ® AIR (and before the 45th day from purchase), you are still not satisfied, please contact us for a RMA number. You will receive a full refund of your purchase price less shipping costs (or as directed by the site where you made the purchase).
Warnings to Hearing Aid Dispensers A hearing aid dispenser should advise a prospective hearing aid user to Stop Using MDHearingAid® AIR and Consult a Physician if: consult promptly with a licensed physician (preferably an ear specialist) before • Hearing in one or both •...
Important Notice for Prospective Users If you have reservations about your ability to adapt to amplification, you Good health practice requires that a person with a hearing loss have a should inquire about the availability of a trial/rental or purchase/option medical evaluation by a licensed physician (preferably a physician who program.
OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM, TO MDHEARINGAID, 917 W. WASHINGTON BLVD, SUITE 202, CHICAGO, IL 60607 NO LATER THAN MIDNIGHT OF THE 45TH DAY AFTER THE INITIAL TRANSACTION.
Need help?
Do you have a question about the AIR and is the answer not in the manual?
Questions and answers