Honeywell ScanDome ll HTX-3000 Instruction Manual
Honeywell ScanDome ll HTX-3000 Instruction Manual

Honeywell ScanDome ll HTX-3000 Instruction Manual

Keyboard controller

Advertisement

ScanDome ll™ KEYBOARD CONTROLLER
HTX-3000
Instruction Manual
`
HTX-3000
Please read this manual thoroughly before use and keep it handy for future reference.
Rev.2 04/10/05

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell ScanDome ll HTX-3000

  • Page 1 ScanDome ll™ KEYBOARD CONTROLLER HTX-3000 Instruction Manual HTX-3000 Please read this manual thoroughly before use and keep it handy for future reference. Rev.2 04/10/05...
  • Page 2: Warning And Caution

    WARNING AND CAUTION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage"...
  • Page 3: Fcc Compliance Statement

    FCC COMPLIANCE STATEMENT FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT.
  • Page 4: Important Safeguards

    IMPORTANT SAFEGUARDS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
  • Page 5: Table Of Contents

    Table of Contents Chapter 1.0 INTRODUCTION 1.1 Features ---------------------------------------------------------------------- 6 1.2 Unpacking ---------------------------------------------------------------------- 7 Chapter 2.0 INSTALLATION 2.1 Connection Diagram --------------------------------------------------------- 8 2.2 Termination & Dip Switch Setting ---------------------------------------- 12 2.3 Keyboard Setup -------------------------------------------------------------- 13 2.4 Master & Slave Keyboard Setting --------------------------------------- 15 Chapter 3.0 OPERATION 3.1 Keyboard Lock/Unlock ----------------------------------------------------- 16 3.2 Controlling Multiplexer ----------------------------------------------------- 16...
  • Page 6: Features

    Chapter 1 INTRODUCITON 1.1 Features This keyboard controller is capable to control 32 ScanDomeII™ dome cameras and remote control functions for variety of external switching devices like Multiplexer(max 255) etc… The keyboard controller features: • The capability of control a camera’s panning and tilting movement with variable speed from 0.5 °/sec to 90°/sec as well as its zoom, focus, and iris command.
  • Page 7: Unpacking

    1.2 Unpacking Unpack the equipment and make sure all listed items are included in the box. Contents of Keyboard box Keyboard controller ------------------------------- 1 Junction box --------------------------------------- 1 3m cable -------------------------------------------- 2 M4 Self tapping screws ------------------------- 4 Instruction manual --------------------------------- 1 12VDC SMPS &...
  • Page 8: Connection Diagram

    Chapter 2 INSTALLATION 2.1 Connection Diagram 2.1.1 Basic Installation Diagram POWER AC 24V AWG # 24 SIREN POWER AC 24V RS-485 HALF DUPLEX MODE : TX+,TX- LIGHT ALARM OUTPUT SENSOR UP TO 4 ALARM INPUT UP TO 8 ALARM INPUT ALARM INPUT ALARM OUTPUT ALARM OUTPUT...
  • Page 9 2.1.2 Single Multiplexer POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) SPOT MONITOR MAIN MONITOR MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 Figure 3 – Single Multiplexer...
  • Page 10 2.1.3 Single User with Two Multiplexer POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) 1ST MAIN MONITOR SPOT MONITOR 2ND MAIN MONITOR 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 Spot output of the first multiplexer to be connected to 16 input of the second multiplexer.
  • Page 11 2.1.4 Two Multiplexer with Slave Keyboard Controller POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) SPOT MONITOR SPOT MONITOR 1ST MAIN MONITOR FOR SLAVE K/B FOR MASTER K/B 2ND MAIN MONITOR 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 Spot output 1 of the first multiplexer to be connected to 16...
  • Page 12: Termination & Dip Switch Setting

    2.2 Termination & Dip Switch Setting The first and last devices in an installation (dome and keyboard controller) must have the data line terminated by setting the DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2 km. Refer to Figure 7 for setting the dome camera and keyboard controller termination.
  • Page 13: Keyboard Setup

    Sub- Multi- DOME controll plexer Termination Controller SLAVE Factory reserved MASTER Table 1 – S2 Switch Setting 2.3 Keyboard Setup User need to setup network, passwords and special functions such as Uploading and Downloading programmed data from the dome cameras. To enter the Keyboard menu, press Ctrl + Menu. You will see the following menu.
  • Page 14 - Set Baud rate Dome : 2400~230K Correspond with dome setting (9600bps) : 2400~230K DVR485 : 2400~230K DVR232 : 2400~230K Save and Exit Com Ports Select the device to be connected on selected port. Dome : None/Dome … : None/DUPLEX/TRIPLEX/AUX IN/AUX I/O… DVR485 : None/ADR/SDR/IDR/AUX IN/AUX I/O…...
  • Page 15: Master & Slave Keyboard Setting

    2.4 Master & Slave Keyboard setting You can use two keyboards at distant site. Master keyboard should be setup as following procedure. 1. Check for dip switch the 7 of S2 “OFF”. 2. P ▶ ▶ ress Ctrl + Menu. Check Slave KBD setting “ON”. (Network Set Slave Kbd Slave kbd:ON/OFF) Slave keyboard need to setup as following procedure.
  • Page 16: Chapter 3.0 Operation

    Chapter 3 OPERATION 3.1 Keyboard Lock/Unlock (Hidden command) When the user leaves the control desk, he may wish to lock the keyboard controller to prevent unauthorized use. Pressing 777 + Enter will lock the keyboard controller. Pressing 777 + Enter while the keyboard is locked will open the password screen.
  • Page 17 Viewing full screen mode ( m + Mux, n + Main) Select cameras 1 to 16 by pressing the camera number and then Main. The selected camera will appear in the full screen mode and is under control if it was dome camera. Even if no camera is connected to the multiplexer input, the screen will show the camera input (see following example).
  • Page 18: Summary Of Keyboard Control

    In a two multiplexer configuration, 18+Cam will switch camera 18 (second camera on Multiplexer 2) to the spot output of multiplexer 2 and the keyboard controller has control of the selected camera. 31+Cam = camera 15 of the second multiplexer. 3.3 Summary of Keyboard Controls MULTIPLEXER DVR CONTROL...
  • Page 19 Key operation example Ctrl + Menu : Press and hold down Ctrl Key and press Menu Key 1 + Cam : Press 1 Key, Cam Key sequentially Ctrl + Joystick : Press and hold down Ctrl Key while manipulate Joystick Handle Enter + Joystick : Press and hold down Enter Key while manipulate Joystick Handle 3.3.1 Keys for Dome camera Function...
  • Page 20 Overrides auto focus. Moving the Zoom handle reactivates Auto Focus mode. Manual Focus Overrides auto iris. Moving the joystick reactivates Auto Iris mode. Manual Iris Zoom control. Zoom Twist Zoom control (proportional to position).(HID2404CZx model only). Up / Down Tilt control, Cursor Up / Down in the PGM. menu Left / Right Pan control, Cursor Left / Right or Page scroll in the PGM.
  • Page 21: Appendix A Trouble Shooting

    Appendix A Trouble Shooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.
  • Page 22: Appendix B Specification

    Appendix B SPECIFICATION Power Consumption 12VDC, 5W Control Method RS-485, RS-232C Baud Rates 2400~230K bps Operating Temperature 0°C to 50°C(32 F to 122 Humidity 0 to 90%RH(non-condensing) Storage temperature -20°C to 60°C(-40 F to 122 Dimension 380 x 168 x 96 (mm) Shipping Dimension 452 x 283 x 162 (mm) Unit Weight...

Table of Contents