Reboot

Software printer restart
Command:
[ESC] $R

Get printenergy-offset (permanent)

Returns the actual used printenergy-offset.
Command:
[ESC] $op
Returns:
The actual used printenergy-offset in ASCII characters ending with [CR].

Get eraseenergy-offset (permanent)

Returns the actual used eraseenergy-offset
Command:
[ESC] $ol
Returns:
The actual used eraseenergy-offset in ASCII characters ending with [CR].

Set temporary printenergy-offset (NOT permanent)

Set the printenergy-offset to adapt the printer to other materials.
This value is stored NON-permanent, and is discarded after reset and power
down.
Command:
[ESC] $OT [c] [xxx]
[c] ... ASCII-characters coding the sign. '+' or '-'
[xxx] ... ASCII-characters coding printenergy-offset. (Valuerange: 000 - 100 )