Schedule Of Failure Alarm & Its Disposal - Midea G01 Service Manual

Midea g01; g02; g03 drum washing machine
Hide thumbs Also See for G01:
Table of Contents

Advertisement

6.TROUBLESHOOTING
6.3 Schedule of failure alarm & its disposal
The alarm display is as below :
Display
Description
LED
Water injecting
problem when
washing (water
E10
injecting time
exceeds 7
minutes)
Overflow protection
The water
E12
level exceed
overflow level.
Drain problem
while washing
E21
(drain time
exceeds 3 minutes)
Door lock
E30
problem
Motor stalling
:
warning Motor
E60
try to start
working 5 times
every 1 min
Speed measuring
signature lost
:
warning PCB
E61
cannot detect
speed signature
during working
Please call up the service line if there is any other problem.
Reason
Tap is not opened or water
flows too slowly.
Inlet valve filter is blocked.
Inlet pipe is twisted.
If water is not supplied
Please call up service line if there are still troubles.
The machine lock the door
close inlet valve motor
,
stop working drain water
.
in error status
Please call up service line if there are still troubles.
Outlet hose is blocked or twisted
Drain pump is blocked
Please call up service line if there are still troubles.
Door is not closed properly.
Please call up service line if there are still troubles.
The machine lock the door
close inlet valve motor
,
stop working drain water
.
in error status
.
Please call up service line if there are still troubles.
The machine lock the door
close inlet valve motor
,
stop working drain water
.
in error status
.
Please call up service line if there are still troubles.
Open the tap or wait till
the water supply
becomes normal.
Check inlet valve filter.
Straighten the water pipe
Check the other taps in
the room.
,
.
-
1 Re start machine
,
.
2 Change inlet valve
Wash and straighten outlet hose.
Wash drain pump filter
Restart after the door is closed
,
1 Check motor wire
,
2 Change PCB
3 Change motor
,
1 Check motor wire
,
2 Change motor
Solution
.
.