5.UNPACKING WAYS OF MAIN PARTS
Operation step
Picture
14 Undo the upper
counterweight
(4.5kg counterweight)
(4.5kg counterweight)
① Undo the top cover
(methods as followed).
② Remove three screws
fit on the upper counterweight
and then pull out the upper
counterweight.
(5.0/6.0/7.0kg counterweight)
(5.0/6.0/7.0kg counterweight)

15 Undo the absorber pin

① Undo the front plate
(methods as followed).
② Use pliers to pinch the
absorber pin's
protuberance, and knock
the absorber pin out from
back lightly; in the same
way, remove the other one.

16 Undo the filter

① Open the filter cover.
② Rotate the filter knob
anticlockwise, and then
pull
out the filter.

17 Undo the drain pump

① Undo the top cover,
control panel, lower cover
and front plate(methods as
followed).
② Nip out clamp between
the drain hose and the
drain pump, and then pull
out the drain hose.