334 – AL Wiring Cylinder B4
Yellow alarm; warning
Cause
Short circuit in cylinder injector
wiring. Result: Misfiring.
335 – AL Wiring Cylinder B5
Yellow alarm; warning
Cause
Short circuit in cylinder injector
wiring. Result: Misfiring.
336 – AL Wiring Cylinder B6
Yellow alarm; warning
Cause
Short circuit in cylinder injector
wiring. Result: Misfiring.
341 – AL Open Load Cylinder A1
Yellow alarm; warning
Cause
Open circuit in cylinder injector
wiring. Result: Misfiring.
342 – AL Open Load Cylinder A2
Yellow alarm; warning
Cause
Open circuit in cylinder injector
wiring. Result: Misfiring.
343 – AL Open Load Cylinder A3
Yellow alarm; warning
Cause
Open circuit in cylinder injector
wiring. Result: Misfiring.
ZKP-Number: 1.8004.533
Corrective action
u Check solenoid valve.
ZKP-Number: 1.8004.534
Corrective action
u Check solenoid valve.
ZKP-Number: 1.8004.535
Corrective action
u Check solenoid valve.
ZKP-Number: 1.8004.540
Corrective action
u Check solenoid valve.
ZKP-Number: 1.8004.541
Corrective action
u Check solenoid valve.
ZKP-Number: 1.8004.542
Corrective action
u Check solenoid valve.
MS15033/01E 2014-02 | Troubleshooting | 55