  • Page 1 Short User Manual - english Software version B3 and above D12501-03 This document is not to be reproduced in whole or in part without permission in writing from:...
  • Page 2: Table Of Contents

    General use TANDBERG Videoconferencing System Contents General use ..................3 Start-up screen ....................3 Making and ending calls .................. 4 Directory ......................6 Do Not Disturb / Sleep Mode ................7 Adjusting volume ..................... 7 Microphone on/off .................... 7 View outgoing video (selfview) ................ 7 Controlling the Main Camera ................
  • Page 3: General Use

    TANDBERG Videoconferencing System General use General use Your system should be in standby mode. When in standby mode, pressing any key or picking up the remote control will wake up the system. An incoming call will also wake up the system. If the system does not respond, make sure the system is switched on.
  • Page 4: Making And Ending Calls

    General use TANDBERG Videoconferencing System Making and ending calls Making a call connect To make a call, enter the number or the IP-address of the unit you wish to call using the Dialing keys and press C ONNECT Net: Auto Quality: Auto To make a call via a LAN, enter an IP-address by using a * as the ‘dot’...
  • Page 5 TANDBERG Videoconferencing System General use Selecting / setting default number of channels YPE OF CALLS TANDBERG 6000/8000: The default call quality setting ‘Auto’ will be used if no specific Auto 384kbps on ISDN/768kbps on LAN quality is selected. * 768kbps on ISDN-BRI...
  • Page 6: Directory

    General use TANDBERG Videoconferencing System Directory The directory is a local phone book that stores up to 99 directory entries and the last number dialed. directory Press D to bring up the following menu: IRECTORY To find an entry, key in the first letter, for example T, and scroll with the up/down arrows.
  • Page 7: Do Not Disturb / Sleep Mode

    TANDBERG Videoconferencing System General use Add MultiSite* When selecting ‘MultiSite’, an empty MultiSite directory entry is displayed: Enter the MultiSite meeting name. Select ‘Add Site’ to add a site to the meeting by searching for point-to-point entries in the directory list. Select ‘Quality’ to override the suggested bandwidth per site.
  • Page 8: Controlling The Main Camera

    General use TANDBERG Videoconferencing System Controlling the Main Camera Moving / zooming camera To control the Main Camera use the keys below: for pan/tilt and for zooming. zoom Selecting video sources main cam doc cam Press: to select a video source.
  • Page 9: Duo Video

    TANDBERG Videoconferencing System General use Duo Video * Duo Video is useful if you want to display live video from your document camera or another camera in addition to live video of yourself. Add Duo Video • Press any other video source than used on the main connection during a call. This will open Duo Video directly if the far end supports the automatic Duo Video functionality.
  • Page 10: Multisite (Mcu)

    General use TANDBERG Videoconferencing System MultiSite (MCU)* The system has a built-in multipoint conference unit (MCU), MultiSite, which has the capability to establish meetings with up to 4 video sites (5 if at least one site is a telephone call, ISDN/analogue/mobile). The video calls in a conference must be connected using the same bandwidth.
  • Page 11 TANDBERG Videoconferencing System General use Adding an extra site - dial in O FIND THE DIAL IN NUMBERS FOR THE ULTI To dial in to the MultiSite on ISDN-BRI: ‘M ’ ‘S ’ PRESS YSTEM • Site 2 must dial MultiSite Number 2.
  • Page 12: Mcu Functions

    General use TANDBERG Videoconferencing System MCU functions RESS ANY UICK KEY WHEN IN A MULTIPOINT CONFERENCE TO ACTIVATE THE UICK This menu provides access to the most commonly used MCU functions. If ‘ Request Floor’ is selected, ‘Request Floor’ will change to ‘Release Floor’.
  • Page 13: Installation

    • Japan only: This equipment is approved by Japanese Approvals Institute for Telecommunications Equipment (JATE), approval number TANDBERG 550: C01-0187JP, TANDBERG 880: C01-0188JP, TANDBERG 1000: C01-0264JP, Codec 2500 (TTC6-02): C01-0186JP, Codec 6000 (TTC6-01): C01-0185JP and should be used in accordance with the instructions any other usage will invalidate the approval.
  • Page 14: Connecting Cables - 2500/6000

    Installation TANDBERG Videoconferencing System Connecting cables - 2500/6000 All cables needed in standard configuration are connected to the codec. Connect these cables to the other parts of the system: 1. Power cable Connect the system power cable and monitor power cable to an electrical distribution socket.
  • Page 15: System Configuration

    TANDBERG Videoconferencing System Installation System configuration • Switch the system on. Product logo and a power up menu will be displayed. • Enabled but unused ISDN lines (lines not active) should be disabled: menu ‘T ’, ‘N ’, ‘ISDN-BRI ’. S...
  • Page 16: Lan Configuration

    Installation TANDBERG Videoconferencing System ISDN-BRI Settings ISDN-BRI ANDATORY SETTINGS NOTE O MAKE SURE YOUR SYSTEM WILL WORK PROPERLY ISDN-BRI, USING MAKE THE FOLLOWING SETTINGS ISDN SWITCH TYPE ISDN (+ SPID NTER LINE NUMBERS S IF REQUIRED ISABLE UNUSED LINES ISDN switch type Select the type of ISDN network connected to your unit.