Minimum Clearances To Combustibles - Outdoors Outdoor 42 Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

installatiOn
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace be installed only in accordance with these instructions.
caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT
be recessed into combustible or non combustible
construction.
B
D
C
10

MINIMUM cLEARANcES TO cOMBUSTIBLES

Od42 clearance requirements
clearance:
A: Sidewall
B: ceiling
c: Mantel height (min.)
D: Mantel Depth (max.)
E: Alcove Width
57"(1148mm)
F: Alcove Depth
Notes:
A
E
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace be
installed only in accordance with these instructions.
Dimension
Measured From:
11" (203mm)
Side of Fireplace Opening
36" (914mm)
Top of Fireplace Opening
18" (457mm)
Top of Fireplace Opening
12" (304mm)
From Wall
Wall to Wall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
0"
No Hearth Required
B
F
WARNING
Fire hazard is an extreme risk
A
E
F
Alcove
OD42 Outdoor Gas Fireplace