12-10. Warning or Shutdown Display
45 60
30
75
1
90
15
105
Oil Pressure
6
0 of
7
9
Dm1. DiagnosticString
Prev
11
12
1 of
Low oil pressure warning threshold
Prev
OM-262 752 Page 66
0
PSI
5
Warning
0
SPN:
0
FMI
Next
Hide
Warning
1
SPN:
100 FMI
exceeded
Next
Hide
2
3
4
8
0
10
OC:
0
Ack
14
13
1
OC:
1
Ack
1
Oil Pressure Display
2
Fault Warning Indicator
The warning symbol appears on the
display when an engine condition
approaches a shutdown condition.
3
Fault Shutdown Indicator
The shutdown symbol appears on
the display when a severe engine
fault can cause shutdown.
The 6-up or 1-up screen with fault
indicator is shown briefly and auto-
matically advances to the fault dis-
play.
4
Fault Display
5
Level Of Fault
6
Indicates Number Of Faults
7
Suspect Parameter Number
8
Failure Mode Identifier
The SPN and FMI numbers are
generated by the engine controller
according to the J1939 standard.
Typical
faults
are
listed
Table 12-1.
9
Diagnostic Description
10 Occurrence Count
For non−critical faults, the number
of occurrences can accumulate
11 Previous Function Button
12 Next Function Button
13 Hide Function Button
Non−critical faults can be hidden.
14 Acknowledge Function Button
To acknowledge the fault and ad-
vance the display to the 1-up or
6-up display, press the Ack function
button and then the Hide function
button.
.
The condition that caused the
warning or shutdown must be
remedied before operation can
continue.