Power up the server (on page 20).
13.

Processor option

The server supports single-processor and dual-processor operations.
CAUTION:
should attempt to replace or install the processor in this server.
CAUTION:
a processor socket cover and a processor blank, or a processor and a heatsink.
CAUTION:
configurations must contain processors with the same part number.
IMPORTANT:
installing the processor.
IMPORTANT:
In a multiprocessor configuration, to optimize system performance, HP recommends balancing the total
capacity of the DIMMs across the processors.
To install the component:
Power down the server (on page 20).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 20).
o
Remove the server from the rack (on page 22).
o
Remove the access panel (on page 24).
4.
Remove the air baffle (on page 27).
5.
To avoid damage to the processor and system board, only authorized personnel
To prevent possible server overheating, always populate each processor socket with
To prevent possible server malfunction and damage to the equipment, multiprocessor
If installing a processor with a faster speed, update the system ROM before
Processor socket 1 must be populated at all times or the server does not function.
Hardware options installation 73